7.3RATE/VOLTAGE CONTROL SWITCH
The Rate/Voltage Control switch on the
Ensure that the voltage setting selected matches the voltage of the battery in- tended for charging.
Select the amperage rate that suites your application as described below:
12 V, 40 AMP TEST / PRUEBA
12 V
2 AMP
OFF
ARRÊT
APAGADA
12 V, 60 AMP BOOST CHARGE CHARGE D’APPOINT CARGA DE REFUERZO
12 V, 200 AMP
ENGINE START
DÉMARRAGE
ARRANQUE
Rate/Voltage Control Switch
SLOW CHARGE (Continuous)
2 AMP: For
FAST CHARGE (Continuous)
40 AMP: For charging automotive style, regular and
BOOST CHARGE & ENGINE START (Duty Cycle)
60 AMP: For brief, high output charging. Follow BOOST CHARGE ratings (min/max, On/Off times) on charger’s front label. Refer to Quick Reference Guide for more details.
200 AMP: For automotive engine starting/cranking assist only. Follow ENGINE START ratings (min/max, on/off times) on charger’s label. Refer to the Quick Reference Guide and paragraph 7.4 for more details.
WARNING: At higher AMP rates, it becomes easier to boil and overcharge the battery. do not leave the charger unattended. Refer to the battery manufacturer’s charging instructions. Use the Charging Time Chart on the Table of Contents page, or the calculation in Section 12, to determine how long to charge. Do not leave on boost charge any longer than necessary or damage to battery will result.
7.4ENGINE START
The ENGINE START setting provides a high current suitable for
If the engine fails to start within 3 to 5 seconds, stop cranking. Return charger to the fast charge setting (40 AMP), and charge battery for another 5 minutes.
If the engine fails to start after a second or third attempt, disconnect the charger. Before replacing the battery, use a battery tester to test it.