Handlebars

 

Handlebars

If tests reveal no other issues, Handle-

 

 

bars should be replaced.

Unit operates but Telemet-

Chest Strap (optional)

Strap should be “POLAR®” compat-

ric HR not displayed

 

ible and uncoded. Make sure strap is

 

 

directly against skin and contact area

 

 

is wet.

 

 

 

 

Interference

Try moving unit away from sources of

 

 

interference (TV, Microwave, etc).

 

 

 

 

Replace Chest Strap

If interference is eliminated and HR

 

 

does not function, replace strap.

 

 

 

 

Replace Console

If HR still does not function, replace

 

 

Console.

 

 

 

Console displays “E2” error

Check data cable integrity

All wires in cable should be intact. If any

code

 

are cut or crimped, replace cable.

 

 

 

 

Check data cable

Be sure cable is connected securely

 

connections/orientation

and oriented properly. Small latch on

 

 

connector should line up and snap into

 

 

place.

 

 

 

 

Console Electronics

If tests reveal no other issues, Console

 

 

should be replaced.

 

 

 

No speed/RPM reading,

Check data cable integrity

All wires in cable should be intact. If any

Console displays “Please

 

are cut or crimped, replace cable.

Pedal” error code

 

 

 

 

 

 

Check data cable

Be sure cable is connected securely

 

connections/orientation

and oriented properly. Small latch on

 

 

connector should line up and snap into

 

 

place.

 

 

 

 

Check magnet position

Magnet should be in place on pulley.

 

(requires shroud removal)

 

 

 

 

 

Check Speed Sensor (re-

Speed sensor should be aligned with

 

quires shroud removal)

magnet and connected to data cable.

 

 

Realign sensor if necessary. Replace if

 

 

there is any damage to the sensor or

 

 

the connecting wire.

 

 

 