SCCG50 & SCCP50
Service Manual
Electrical
The ice machine is supplied with a power cord. Do not remove the grounding pin from the cord’s plug. Do not use extension cords. Follow all codes.
Connect the machine to its own 115 volt, 15 amp circuit.
1.If the electrical outlet for the ice maker is behind the unit, plug in the unit.
2.Position the unit in the installation opening.
3.Turn on the water supply. Make sure that the ice maker is plugged in and the power is on.
4.Slide unit into installation opening, paying careful attention to water supply and drain connections. Do not kink!
5.Pour a couple of quarts of water into the ice storage bin; on drain pump equipped machines the drain pump should start and water should pump out. Check for leaks.
6.Replace the service access panel.
7.Level the unit as needed.
Installation check list:
1.Has the unit been connected to the proper water supply?
2.Has the water supply be checked for leaks?
3.Has the unit been connected to a drain?
4.Has the drain been tested for flow and leaks?
5.Has the unit been connected to the proper electrical supply?
6.Has the unit been leveled?
7.Have all packing materials been removed from the machine?
8.Has the door covering been installed?
Initial Start Up
1.Turn on the water supply.
2.Switch on the electrical power.
3.Push and release the On/Off switch to start the machine. The Ice Making light next to the On/Off switch will glow Green.
4.Water will begin to flow into the unit. When the reservoir is full, water will start to drain from the machine. After a few minutes the compressor, water pump and fan motor will begin to operate and the first ice making cycle will have begun.
No adjustments are needed.
After about a half hour, ice will fall into the ice storage bin. The machine makes 24 cubes per batch. It is normal for the first batches of ice to melt, that continues until the bin has cooled. It will take 8 to 10 hours of continuous run time to fill the ice bin. When the bin is full of ice, the ice machine will shut off. It will automatically restart when the ice level falls, either from use or normal meltage.
June 2008