Scotsman Ice service manual Removal and Repair, SCCG50 & SCCP50, Electrical Shock, Hazard

Models: SCCP50 SCCG50

1 32
Download 32 pages 60.01 Kb
Page 28
Image 28
Removal and Repair

 

 

 

 

 

 

 

 

SCCG50 & SCCP50

 

 

 

 

 

 

 

 

Service Manual

Removal and Repair

 

 

 

Bin Thermostat

9.

Reverse to reassemble.

1.

Disconnect electrical power.

 

Curtain

 

 

 

 

 

 

1.

Shut unit off.

 

 

 

 

 

 

 

 

 

 

 

 

2.

Loosen both thumbscrews holding curtain

 

 

 

 

Electrical Shock

 

 

 

 

 

 

 

bracket to freezing chamber.

 

 

 

 

Hazard.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect electrical

 

 

 

 

 

 

 

 

power before

 

3.

Pull out and remove curtain with bracket from ice

 

 

 

 

beginning removal

 

 

machine.

 

 

 

 

 

 

4.

Reverse to reassemble.

 

 

 

 

 

2.

Remove service panel.

3.

Remove back panel.

 

Spray Platform

 

 

 

 

 

 

1.

Remove curtain.

Note: If unit is built in it must be pulled out to

 

 

 

change the bin thermostat.

2.

Lift spray platform up until it disconnects from its

 

 

 

 

 

 

 

 

 

 

 

 

4.

Pull cap tube out from the back of the ice

 

fitting.

 

 

 

storage bin and cap tube holder.

3.

Pull forward and remove from the ice machine.

 

 

 

 

 

 

5.

Remove two screws and the bin thermostat

4.

Reverse to reassemble.

contact section from its mounting bracket.

 

 

 

6.

Disconnect two wires from the bin thermostat

 

Water Pump

 

 

 

contact section and remove the thermostat from

1.

Remove spray platform

the ice machine.

 

 

 

7.

Reverse to reinstall.

2.

Remove back panel.

 

 

 

 

 

 

 

 

 

 

 

Inlet Water Solenoid Valve

 

Note: If unit is built in it must be pulled out to

 

change the water pump.

 

 

 

 

 

 

 

1.

Disconnect electrical power.

 

 

 

 

 

 

 

 

 

 

 

 

3.

Disconnect power and ground wires from pump

2.

Remove service panel.

 

motor.

3.

Shut water supply OFF.

4.

Rotate pump body CW and lift up to remove it.

4.

Disconnect inlet water supply tube from inlet

5.

Reverse to reassemble.

water solenoid valve.

5.Unplug wire harness from valve coil.

6.Remove two screws holding valve to chassis.

7.Squeeze hose clamp larger and push away from solenoid valve outlet.

8.Pull hose from outlet of valve.