SCCG50 & SCCP50

Service Manual

Removal and Repair - Cabinet Removal

Certain components require the removal of the cabinet for repair access.

1.If the machine is in a freeze mode, perform a manual harvest.

2.Remove all ice.

3.Drain reservoir.

4.Remove service panel and kick plate.

5.Remove back panel.

6.Disconnect electrical power.

Electrical Shock

Hazard.

Disconnect electrical power before beginning removal

7.Disconnect water and drain tubing.

8.Remove door.

9.Remove top panel.

10.Remove controller box cover.

11.Disconnect thermistor from controller, pull wire back to suction line.

12. Remove curtain & hanger.

13.Locate elbows where water flows onto the evaporator platen.

Clip

Inlet

Elbow

14.Pull clip up. Push inner elbow back and rotate it until it points straight up, then push it back through the hole in the back of the freezing compartment.

Thermistor

Connector

Inlet

Inner

Elbow

Elbow

15. Pull water inlet elbow out of inner elbow.

June 2008

Page 30

Page 30
Image 30
Scotsman Ice SCCG50, SCCP50 service manual Removal and Repair Cabinet Removal