SCCG50 & SCCP50

Service Manual

Performance Information

Freeze Cycle, Minutes

 

 

Air Temperature

 

 

100

90

80

70

60

50

 

 

 

 

100

37-38

36-37

34-35

32-33

31-32

29-30

 

90

 

36-37

35-36

33-34

31-32

30-31

28-29

 

80

 

36-35

32-33

30-31

28-29

27-28

26-27

Water

70

 

32-33

28-29

27-28

25-26

23-24

22-23

Temperature

 

60

 

27-28

25-26

24-25

22-23

20-21

19-20

 

 

 

50

 

20-21

19-20

18-19

17-18

16-17

15-16

 

40

 

18-19

17-18

16-17

15-16

15-16

15-16

 

 

 

 

 

 

 

 

Harvest Cycle, Seconds

 

 

Air Temperature

 

 

100

90

80

70

60

50

 

 

 

 

80

-100

55-60

60-70

70-80

80-90

90-100

110-115

Water

70

- 80

65-75

70-80

75-85

85-95

95-105

115-120

Temperature

50

- 70

70-80

75-85

85-95

125-135

140-150

160-170

 

 

40

- 50

100-120

115-125

130-140

150-170

180-200

210-230

 

 

 

 

 

 

 

 

Total Cycle, Minutes

 

 

Air Temperature

 

 

100

90

80

70

60

50

 

 

 

 

100

38-39

37-38

36-37

34-35

33-34

31-32

 

90

 

38-39

36-37

35-36

33-34

32-33

30-31

 

80

 

37-38

33-34

31-32

30-31

29-30

27-28

Water

70

 

33-34

29-31

28-29

26-27

25-26

24-25

Temperature

 

60

 

29-30

27-28

25-26

24-25

22-23

21-22

 

 

 

50

 

21-22

20-21

19-20

19-20

19

18-19

 

40

 

20-21

19-20

19

18-19

19

19-21

Ice per cycle: 1 lb

Water drained / cycle: Varies by harvest cycle length and purge setting. Typical amounts are @ 70/50 = 52 oz. @ 90/70 = 13 oz

Compressor amps: 2.6 - 3.2

June 2008

Page 23

Page 23
Image 23
Scotsman Ice SCCP50, SCCG50 service manual Performance Information