SCCG50 & SCCP50
Service Manual
Service Diagnosis
Makes excessive noise
| Problem | Likely Cause | Probable Solution | |
| Fan blade vibrates | Blade is bent | Replace fan blade | |
| Fan motor mount is broken | Replace motor mount | ||
| 
 | |||
| Compressor vibrates | Mounting loose | Check mounting | |
| Water pump vibrates | Pump bearings worn | Replace pump | |
| Panels vibrate | Mounting screws loose | Tighten screws | 
Makes ice, does not harvest
Problem
Likely Cause
Probable Solution
| Ice wrong size | Environment changed | Adjust cube size | |
| 
 | 
 | Check voltage to coil when unit is | |
| 
 | Hot gas valve does not open | in harvest, check controller | |
| Little heat to evaporator | 
 | indicator light. | |
| Water temperature very low | Adjust harvest time | ||
| 
 | |||
| 
 | Fan motor does not stop | Check voltage, replace controller | 
Makes poor quality ice
Problem
Likely Cause
Probable Solution
| Spray pattern poor | Spray jets dirty | Clean jets | 
| Runs out of water | Water leaking from reservoir | Correct leak | 
| High TDS water supply | Groundwater supply | Treat water | 
Makes ice, but melts rapidly
Problem
Likely Cause
Probable Solution
| Restricted drain | Gravity drain hose has air block | Check for kinks or traps | |
| Pooled water in bin | Pump model switch not starting | Check / replace switch | |
| pump | |||
| 
 | 
 | 
June 2008