HONEYWELL SV9541M
IPOWERAPPLIEDTO APPLIANCE
+
I THERMOSTATCALLS FORHEAT
¢
IPRESSURE SWITCHES PROVED OPEN?
ICOMBUSTIONBLOWER ENERGIZED
PRESSURESWITCHESCLOSEDWITHIN30 SEC- ONDS?
+
I
PILOTVALVEOPENS: IGNITORPOWERED(1)
PILOTLIGHTSAND FLAME ISSENSED DURING 90SECOND TRAILFOR IGNITION?
I YES
MAIN VALVEOPENS,
HEATINGFAN "ON" DELAYBEGINS
+
I AFTERDELAY:CIRCULATINGBLOWERSTARTS
FLAME SENSE LOST?
"SMART VALVE" Sequence of Operation
I
WAIT FORPRESSURESWITCHESTO OPEN
_._ | COMBUSTIONBLOWER | J__ | FIVEMINUTE WAIT PERIOD |
I
FAILURETHREESECONDFLAMERECYCLEDELAY,J_
l'_Vl PILOTVALVECLOSES; |
|
PILOT IGNITOROFF | r |
I
YES
|
|
| CIRCULATINGBLOWEROFF AFTER DELAY |
I | I |
| + |
|
| ||
| PILOTAND MAIN VALVECLOSE | 1 |
|
THERMOSTATCALL FORHEAT ENDS
L FLAMETIMES INSENSETHISCALLLOSTFORHEAT?MORETHAN FIVE
COMBUSTIONAIR BLOWER OFF AFTERPOST
PURGE
NO
PILOTAND MAIN VALVECLOSE
+
COMBUSTIONBLOWER DE- ENERGIZEDAFTER 30
SECONDPOST PURGE
+
I CIRCULATINGBLOWEROFF AFTER DELAY
I
IWAIT FOR NEXTCALL FOR HEAT
I
NO
YES
(1) Ignitor "ON" for first 30 seconds of trial for ignition, then "OFF" for next 30 seconds. If the pilot has not lit, it turns back "ON" for the final 30 seconds. The pilot valve remains energized during the entire 90 second trial for ignition.
NOTE: If main limit string opens and takes longer than 2 minutes to close, system goes into I hour wait
period.