HorizontalLeftInstallations

(Dual Certified *9MPD-A4

Models)

NOTE: TRAP MUST BE PRIMED BEFORE OPERATION

Horizontal Trap Connection

 

 

 

"Clamp ears"

Model shown with two

Pointed OUT

 

pressure

switches

 

ipe Combustion Air

 

 

Pipe, (optional)

 

 

5/16" OD

 

 

Rubber

 

Preassembleand

insert intofurnace

 

 

 

 

Blower

 

Supply

 

 

 

 

 

Air

 

 

 

 

Return Air

 

 

 

 

 

 

Vent Pipe

 

 

 

 

PVC Vent

Grommet

 

 

 

 

 

 

 

 

 

Extension Pipe

 

 

 

Transition

 

 

 

 

 

 

 

 

 

 

3/4" Hose & Clamps

25-24-12

 

 

 

 

 

Vent Fitting

 

 

 

 

 

& Clamps Yellow

 

Rubber Couplings

 

 

Plastic

 

& Clamps

 

90° Elbow

 

 

& Clamps

Plastic Cap

DRAIN

SIDE VIEW

 

 

 

 

 

 

11" Section

 

 

 

 

& Clamps

2" PVCPipe

 

_tate

downward

 

 

Condensate

 

 

 

 

 

Trap & Gasket

 

 

 

 

 

(Field Supplied)

DrainLine:

_

Single Pressure Switch

 

 

 

 

Connections

on

 

 

 

 

All models

except 125

 

 

 

angled5° to 10° also.

 

Horizontal Left Installations - (Dual Certified *9MPD) (See Figure 10)

Note: DO NOT make hose connections until the hose routing and

lengths have been determined. Remove the condensate trap and drain hoses from the furnace and secure the drain hoses to the

drain stubs on the trap with the hose clamps (position the clamps as shown in Figure 10). Install the condensate trap/hose assem-

blyto the furnace casing. Hook one side ofthe"clamp ears" on the drain stub through the hole in the casing and push the condensate trap into position. Secure with the two screws. Reconnect the drain hoses to the stubs on the vent fitting and the plastic transi- tion and secure with the clamps.

Relocate the plastic cap and clamp from the vertical transition drain stub to the horizontal transition drain stub on the conden-

sate drain trap. Secure the clamps tightly to prevent condensate leakage. Do not change the cap and clamp on the vent drain stub.

Mount the condensate drain trap in a vertical position to the left side of the furnace using the two screws and gasket that are pro-

vided. Note: The condensate trap will be located under the fur- nace in a vertical position when the furnace is placed horizontally on the left side. If needed, remove the hole plugs from the furnace side panel and relocate to the open set of holes in the opposite side panel.

NOTE: All gaskets and seals must be in place for sealed combus- tion applications.

Remove the 90 ° elbow and vent fitting from the combustion blow- er by loosening the clamps on the vent fitting. Connect the 90 ° el-

bow to the combustion blower using the rubber coupling and cla raps. Note for proper alignment of the vent pipe through the fur- nace, the 90 ° elbow must be installed with the "HORIZONTAL" lettering on the 90 ° elbow facing out. Connect a 11" section of 2" PVC pipe (field supplied) to the 90 ° elbow using the rubber cou- pling and clammps. The PVC pipe will extend through the top pa n- el a bout 11/2". Connect the vent fitting to the end of the 11" section of PVC pipe using the clamp.

NOTE: The 90 ° elbow is approved for use inside the furnace ONLY.

NOTE: The vent fitting MUST be installed with the airflow marking arrow pointed toward the vent pipe, with the drain stub at a 5 ° to 10 ° downward slope.

Plug the upper drain stub on the vent fitting with the yellow plastic cap.

Connect the PVC vent extension pipe to the vent fitting. This pipe

has a built-in channel to assist vent condensate disposal. Align the arrow on the PVC pipe with the airflow marking arrow on the vent fitting. See label on the PVC pipe for proper installation. This pipe may only be shortened if an elbow is used to connect the

[_

440 01 111400

Page 16
Image 16
Sears N9MP1, N9MP2 manual HorizontalLeft Installations, Dual Certified *9MPD-A4, Models, 25-24-12

9MPD, N9MP1, N9MP2 specifications

The Sears N9MP2, N9MP1, and 9MPD are prominent models in the realm of residential heating systems, specifically designed to provide efficient and effective heating solutions. These models are part of Sears' commitment to quality and innovation, making them a popular choice among homeowners seeking reliability and performance.

The N9MP2 is a high-efficiency multi-speed gas furnace that boasts an impressive AFUE (Annual Fuel Utilization Efficiency) rating. This feature allows the furnace to convert a significant portion of fuel into usable heat, which effectively translates to lower energy bills for homeowners. The unit is equipped with a two-stage gas valve that provides increased comfort by adjusting the heating output based on demand, ensuring an even temperature throughout the home.

The N9MP1, like its counterpart, is known for its reliability and efficiency. It offers a single-stage operation that is ideal for homes needing consistent heating without the necessity for the more complex stages present in two-stage systems. This model also has a good AFUE rating, making it a cost-effective solution for families looking to reduce their heating expenses. Its design is tailored for easy installation and maintenance, allowing homeowners to keep their heating systems running at optimal performance without hassle.

The 9MPD model takes a step further with its advanced technology integration. It features a sophisticated control board that allows for easier diagnostics and enhanced system management. The 9MPD is also designed with quiet operation in mind, employing advanced sound-reduction technologies to minimize noise levels during heating cycles. Homeowners will appreciate the peace and quiet it brings, particularly in shared living spaces.

All three models are equipped with high-quality insulation and specialized heat exchangers that enhance their thermal efficiency. Additionally, they are designed with safety features such as automatic shut-off systems and robust flame rollout protection, ensuring a safe heating experience.

In terms of characteristics, these models are generally constructed with durable materials, designed to endure harsh weather conditions while providing consistent heating. They can be connected to various home automation systems, which adds to their appeal for tech-savvy consumers.

In conclusion, the Sears N9MP2, N9MP1, and 9MPD represent a comprehensive lineup of reliable, efficient, and technologically advanced heating systems suitable for contemporary homes. Their dedication to performance ensures that homeowners enjoy a warm and energy-efficient environment throughout the chilly seasons.