Sears N9MP1 Ductwork and Filter, Installation, Control Center Fuse, Fan Delay DIP Switch Settings

Models: 9MPD N9MP1 N9MP2

1 62
Download 62 pages 59.01 Kb
Page 34
Image 34

Fan Delay DIP Switch Settings

COOL ON DELAY:6SEC.

COOL OFF DELAY:60 SEC.

HEATON DELAY:30 SEC.

HEAT OFF DELAY

60SEC 100SEC 140SEC 180SEC 25-23-47

Electrical Connections

NOTE: Junction Box can be

mounted to either the left or right side.

1_5V. aOHL

G_=_nd

[ Low Voltage

;Terl_nn_

:i

25-23-42

7. Ductwork and Filter

CARBON MONOXIDE POISONING HAZARD

Failure to properly seal duct can result in death, personal

injury and/or property damage.

Do NOT draw return air from inside a closet or utility room. Return air duct MUST be sealed to furnace casing.

Installation

NOTE: Design and install air distribution system to comply with

Air Conditioning Contractors of America manuals and/or NFPA pamphlets 90A and 90B or other approved methods that conform to local codes and good trade practices.

1.When furnace supply ducts carry air outside furnace area, seal return air duct to furnace casing and terminate duct outside furnace space.

2.Install air conditioning cooling coil (evaporator) on outlet side of furnace.

Control Center Fuse

The 24V circuit contains a 5-amp, automotive-type fuse located on fan timer board. (See Figure 32) Any electrical shorts of 24V

wiring during installation, service, or maintenance may cause

fuse to blow. If fuse replacement is required, use only a fuse of identical size (5 amp.)

Fan Timer Connections

_- DIP Switch

FUSE_

¢&25-23-41

3.For furnaces installed without a cooling coil it is recom- mended that the outlet duct be provided with a removable access panel. This panel should be accessible when the furnace is installed so the exterior of the heat exchanger can be viewed for inspections. The access panel MUST be sealed to prevent leaks.

4.If separate evaporator and blower units are used, install good sealing dampers for air flow control. Chilled air going

through the furnace could ca use condensation and shorten the furnace life.

NOTE: Dampers (field supplied) can be either automatic or manual. Manually operated dampers MUST be equipped with a

means to prevent furnace or air conditioning operation unless damper is in the full heat or cool position.