Sears 9MPD125L20B1 manual Horizontal Termination, Using Exterior Risers, Vertical Termination

Models: 9MPD100J20B1 N9MP2100J20B1 9MPD050F12B1 N9MP1100J20B1 N9MP1125J20B1 N9MP2050B12B1 9MPD075F12B1 N9MP2100F14B1 N9MP2075B12B1 N9MP1100F14B1 9MPD100J14B1 N9MP1080F16B1 N9MP2080F16B1 N9MP2125J20B1 9MPD080J16B1 N9MP1050B12B1 9MPD125L20B1 N9MP1075B12B1

1 63
Download 63 pages 34.91 Kb
Page 27
Image 27

1,

Install

all couplings,

nipples and elbows using proper proce-

 

dures

for Joining Pipe and Fittings and maintain spacing

 

between vent and

combustion air piping as indicated in

 

Figure 20 through Figure 28.

MIN.

_18" Minimumfor cold climates

 

(substained below 0° F)

MIN.

GRADELEVEL 25-00-05F

ON

SNOW LEVEL

Horizontal Termination

1, Cut two holes. 21/2" for 2" pipe, 3" for 21/2" pipe, or 31/2" for 3" pipe. Do NOT make the holes oversized, or it will be nec- essary to add a sheet metal or plywood plate on the outside with the correct size hole in it.

2, Check hole sizes by making sure it is smaller than the cou- plings or elbows that will be installed on the outside. The couplings or elbows MUST prevent the pipe from being pushed back through the wall.

3.Extend vent pipe and combustion air pipe through the wall 3/4" to 1" and seal area between pipe and wall.

4.Install the couplings, nipple and termination elbows as shown and maintain spacing between vent and combustion air piping as indicated in Figure 20 and Figure 21.

A metal shield is recommended 18" x 18" min. or 18" min. diameter around the vent termination at the exterior wall to protect the house exterior materials from flue product or condensation (freezing) damage.

Using Exterior Risers

1, Install elbows and pipe to form riser as shown in Figure 21.

2.Secure vent pipe to wall with galvanized strap or other rust resistant material to restrain pipe from moving.

3, Insulate pipe with Armaflex or equivalent moisture resistant closed cell foam insulation or Fiberglass insulation if boxed in and sealed against moisture.

.........................................................................!i

i

I Risers°rGradesidewallLeveITerminati°nt° Get Ab°ve sn°wwith

ExteriorLevel

 

 

8"

*

 

 

 

 

 

MIN.

_

"18" Minimum

for cold

climates

 

 

20'

 

(substained

below

F)

 

 

JW MAX

 

 

 

 

8"

MIN.

GRADE LEVEL OR

SNOW LEVEL

25-00-04F

Vertical Termination

1.Figure 22 shows the proper installation and clearances for

vertical vent termination. The vertical roof termination should be sealed with a plumbing roof boot or equivalent flashing. The inlet of the intake pipe and end of the exhaust vent must be terminated no less than 12" above the roof or

snow accumulation level, and 12" away from a vertical wall or other protrusion.

2.If the vent system is installed in an existing chimney make

sure clearances shown in Figure 22 are maintained. Hori-

zontal section before the termination elbow can be ex- tended on the inlet air to provide necessary clearance.

Rooftop Termination

A= 12"Aboveroofor snowaccumulationlevel

B= 8" Min.20'Maximum,,exceptin areaswithextremecoldtemperatures (sustainedbelow0°% the18" Min.

Vent Termination Shielding

Under certain wind conditions some building materials may be af- fected by flue products expelled in close proximity to unprotected surfaces. Sealing or shielding of the exposed surfaces with a cor- rosion resistant material (such as aluminum sheeting) may be re-

quired to prevent staining or deterioration. The protective material should be attached and sealed (if necessary) to the building before attaching the vent terminal.

44001 102004

[_

Page 27
Image 27
Sears 9MPD125L20B1 manual Horizontal Termination, Using Exterior Risers, Vertical Termination, Vent Termination Shielding

9MPD100J20B1, N9MP2100J20B1, 9MPD050F12B1, N9MP1100J20B1, N9MP1125J20B1 specifications

The Sears N9MP1075B12B1, N9MPD125L20B1, N9MP1050B12B1, N9MPD080J16B1, and N9MP2125J20B1 are part of the trusted line of gas furnaces manufactured by Sears, specifically designed to deliver reliable heating solutions for residential applications. These models incorporate cutting-edge technology and robust engineering, making them popular choices among homeowners looking for efficiency and comfort.

One of the main features of these models is their high-efficiency operation. With Annual Fuel Utilization Efficiency (AFUE) ratings exceeding 90%, these furnaces convert a significant portion of fuel into usable heat, thereby reducing energy costs. The N9MP series employs a multi-speed blower system that optimizes airflow for enhanced comfort while minimizing noise levels, ensuring a pleasant indoor environment.

The N9MPD125L20B1 and N9MPD080J16B1 variants highlight their adaptability through dual-stage heating capabilities. This technology allows the furnace to adjust its output based on the thermal demands of the home, preventing energy wastage during milder conditions while providing robust heating during extreme cold spells. The two-stage combustion process not only improves comfort but also contributes to lower greenhouse gas emissions.

Durability is another hallmark of these Sears models. With heavy-duty heat exchangers crafted from high-quality materials, they are built to withstand the rigors of regular use. Additionally, the inclusion of advanced safety mechanisms ensures that the system operates securely, reducing potential risks associated with gas furnaces.

The N9MP2125J20B1 model stands out due to its whisper-quiet operation. Homeowners can enjoy a warm home without the disruptive sound commonly associated with traditional heating systems, thanks to the insulated cabinet design and efficient blower operation.

Furthermore, these models come equipped with user-friendly digital thermostats, which allow precise temperature control and programmable settings, enabling homeowners to tailor their heating needs to fit their lifestyle. The compatibility with smart home systems also adds convenience, enabling users to manage their heating remotely, saving even more energy.

In conclusion, the Sears N9MP1075B12B1, N9MPD125L20B1, N9MP1050B12B1, N9MPD080J16B1, and N9MP2125J20B1 gas furnaces exemplify innovation in heating technology. Their energy-efficient designs, advanced features, and durable construction make them reliable choices for homeowners seeking comfort and sustainability in their heating solutions.