Concentric Termination Kit

NAHA001CV & NAHA002CV Venting

........................................................Table for N9MP2 Models

50,000 & 80,000 Btuh Furnaces

NAHA002CV - 35'& (4) 90 ° elbows with 2" PVC pipe or NAHA001CV - 65'& (4) 90 ° elbows with 3" PVC pipe

75,000 Btuh Furnaces

NAHA002CV - 20'& (2) 90 ° elbows with 2" PVC pipe or NAHA002CV - 35'& (4) 90 ° elbows with 2" PVC pipe & Long Vent Kit (See Tech. Manual) or

NAHA001CV - 65'& (4) 90 ° elbows with 3" PVC pipe

100,000 Btuh Furnace

NAHA001CV - 35'& (4) 90 ° elbows with 3" PVC pipe or NAHA001CV - 65'& (4) 90 ° elbows with 3" PVC pipe & Long Vent Kit (See Tech. Manual)

125,000 Btuh Furnace

NAHA001CV - 35' & (4) 90 ° elbows with 3" PVC pipe

1.Do not include the field supplied 45 ° elbow in the total elbow count,

2,

If

more

than

four

elbows

are

required,

reduce

the length

of

both

the inlet

and

the exhaust

pipes

five

feet

for

each

 

 

additional

elbow

used,

 

 

 

 

 

 

 

3,

Elbows

are

DWV

long

radius

type

for

2" and

3"

vents,

 

NOTE: Feet of pipe is whichever pipe run is the longest, either inlet or outlet side.

If assembly needs to be extended to meet height or side wall thick-

ness requirement, the two pipes supplied in the kit may be re- placed by using the same diameter solid, single (no coupling

connections) field supplied SDR-26 PVC (ASTM D2241) pipes. Do not extend dimension D more than 60". (See Figure 47)

Do not use field supplied couplings to extend the pipes.

Airflow restriction will occur and the furnace pressure switch

may cause intermittent operation.

5, Partially assemble the concentric vent termination kit. Clean and cement the parts using the procedures for Join- ing Pipe and Fittings section of the manual. A) Cement the Y

Concentric fitting to the 4" diameter kit pipe. (See Figure 48) B) Cement the 3" rain cap to the 21/2" diameter

kit part. (See Figure 48) NOTE: A field supplied stainless steel screw may be used to secure the rain cap to the pipe

instead of cementing when field disassembly is desired for cleaning (See Figure 48)

Rain Cap to Vent Pipe Assembly

Drill clearance hole in rain

cap and pilot hole in vent pipe.

 

_el

screw

25-22-02

(Field

supplied)

 

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in death, personal injury and/or property damage.

When using the alternate screw assembly method, drill a clearance hole in the rain cap and a pilot hole in the vent pipe for the screw size being used. Failure to drill adequate holes may cause cracking

of the PVC components, allowing flue gases to be recirculated.

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in death, personal injury and/or property damage.

Do not operate the furnace with the rain cap removed as recirulation of the flue gases may occur. Water may also collect inside the larger

combustion air pipe and flow to the burner enclosure.

6.Install the Y concentric fitting and the pipe assemblythrough the structure's hole. For vertical termination, install the parts

through the field supplied roof boot/flashing. NOTE: Do not allow insulation or other materials to accumulate inside the

pipe assembly when installing through the structure's hole.

7.Securethe assemblyto the structure as shown in Figure 46 or Figure 50 using field supplied metal strapping or equiva- lent material.

NOTE: Ensure the termination height is above the roof sur-

face or anticipated snow level as shown in Figure 46 for

vertical termination. Ensure the termination location clear-

ance dimensions are as shown in Figure 49 and Figure 50 for horizontal termination.

Concentric Vent and Combustion-

Air Side Termination

Roof Overhang

Maintain12" clearanceabove highestantici- patedsnow level or gradewhichever is greater.

25-22-02

44001 102004

[_

Page 47
Image 47
Sears N9MP1100F14B1 Rain Cap to Vent Pipe Assembly, Concentric Vent and Combustion Air Side Termination, Roof Overhang

9MPD100J20B1, N9MP2100J20B1, 9MPD050F12B1, N9MP1100J20B1, N9MP1125J20B1 specifications

The Sears N9MP1075B12B1, N9MPD125L20B1, N9MP1050B12B1, N9MPD080J16B1, and N9MP2125J20B1 are part of the trusted line of gas furnaces manufactured by Sears, specifically designed to deliver reliable heating solutions for residential applications. These models incorporate cutting-edge technology and robust engineering, making them popular choices among homeowners looking for efficiency and comfort.

One of the main features of these models is their high-efficiency operation. With Annual Fuel Utilization Efficiency (AFUE) ratings exceeding 90%, these furnaces convert a significant portion of fuel into usable heat, thereby reducing energy costs. The N9MP series employs a multi-speed blower system that optimizes airflow for enhanced comfort while minimizing noise levels, ensuring a pleasant indoor environment.

The N9MPD125L20B1 and N9MPD080J16B1 variants highlight their adaptability through dual-stage heating capabilities. This technology allows the furnace to adjust its output based on the thermal demands of the home, preventing energy wastage during milder conditions while providing robust heating during extreme cold spells. The two-stage combustion process not only improves comfort but also contributes to lower greenhouse gas emissions.

Durability is another hallmark of these Sears models. With heavy-duty heat exchangers crafted from high-quality materials, they are built to withstand the rigors of regular use. Additionally, the inclusion of advanced safety mechanisms ensures that the system operates securely, reducing potential risks associated with gas furnaces.

The N9MP2125J20B1 model stands out due to its whisper-quiet operation. Homeowners can enjoy a warm home without the disruptive sound commonly associated with traditional heating systems, thanks to the insulated cabinet design and efficient blower operation.

Furthermore, these models come equipped with user-friendly digital thermostats, which allow precise temperature control and programmable settings, enabling homeowners to tailor their heating needs to fit their lifestyle. The compatibility with smart home systems also adds convenience, enabling users to manage their heating remotely, saving even more energy.

In conclusion, the Sears N9MP1075B12B1, N9MPD125L20B1, N9MP1050B12B1, N9MPD080J16B1, and N9MP2125J20B1 gas furnaces exemplify innovation in heating technology. Their energy-efficient designs, advanced features, and durable construction make them reliable choices for homeowners seeking comfort and sustainability in their heating solutions.