Sears 9MPD080J16B1, N9MP2050B12B1 Multi Vent Termination Clearances, Cold Weather -O F & below

Models: 9MPD100J20B1 N9MP2100J20B1 9MPD050F12B1 N9MP1100J20B1 N9MP1125J20B1 N9MP2050B12B1 9MPD075F12B1 N9MP2100F14B1 N9MP2075B12B1 N9MP1100F14B1 9MPD100J14B1 N9MP1080F16B1 N9MP2080F16B1 N9MP2125J20B1 9MPD080J16B1 N9MP1050B12B1 9MPD125L20B1 N9MP1075B12B1

1 63
Download 63 pages 34.91 Kb
Page 28
Image 28

Multi Vent Termination Clearances

When two (2) or more furnaces are vented near each other, each furnace must be individually vented.

Two (2) vent terminations may be installed as shown in Figure 23, Figure 24, Figure 25, Figure 26, Figure 27 and Figure 28, but the next vent termination must be at least 36" away from first 2 ter- minations. It is important that vent terminations be made as shown

to avoid recirculation of flue gases.

Sidewall Inlet Vent and Exhaust-Air

Termination with Exterior Risers

18" Min. for Cold Climates_

(SustainedBelow 0° F)

8" Min.

Grade or

Snow Level

I c°mbusti°nc°ncentricRoof -AirTerminationventand

12"Min. Grade ori Snow Level

Combustion

Air

Dimension "A" is touching or 2" maximum separation.

Concentric Vent and Combustion-

Air Sidewall Termination

Exhaust

Vent25-22-02d

Dimension "A" is touching or 2" maximum separation.

Sidewall Inlet Vent and Exhaust-

Air Termination

18"ColdClimatesMin.for (SustainedBelow0o F

12" Min. Grade or

Snow Level

FF_iDiDimension"A" is touchin9 or 2" maximum separation.

Dimension "A" is touchin9 or 2" maximum separation.

iiiil

Rooftop Inlet Vent and Exhaust-

Air Termination

18" Min.forColdClimates _ \ _- (SustainedBelow0° F)

8"Min.

20'Max.

/

12" Min.

Exhaust

Level

25-22-43

Recommended Alternate

Installation for Sustained

Cold Weather (-O ° F & below)

OVERHANG

EXHAUST 12" MIN.

IN ET

Level

OR Snow Level

FRONT VIEW

SIDE VIEW

 

Same Joist

Space

25-23-73

440 01 1020 04

Page 28
Image 28
Sears 9MPD080J16B1 manual Multi Vent Termination Clearances, Concentric Vent and Combustion Air Sidewall Termination