Sears N9MP2080F16B1 SubbasesforCombustibleFloorsDimensions, FloorDimensions, Furnace Subbase

Models: 9MPD100J20B1 N9MP2100J20B1 9MPD050F12B1 N9MP1100J20B1 N9MP1125J20B1 N9MP2050B12B1 9MPD075F12B1 N9MP2100F14B1 N9MP2075B12B1 N9MP1100F14B1 9MPD100J14B1 N9MP1080F16B1 N9MP2080F16B1 N9MP2125J20B1 9MPD080J16B1 N9MP1050B12B1 9MPD125L20B1 N9MP1075B12B1

1 63
Download 63 pages 34.91 Kb
Page 37
Image 37

SubbasesforCombustibleFloorsDimensions

 

 

 

 

SubbaseforCombustible

Subbase

for Combustible

 

FloorDimensions

 

 

 

 

 

Floors

Part

Number

H*

J*

K**

 

 

 

 

 

Furnace

Subbase

 

 

 

 

NAHH001SB

 

1511/16

283/4

149/16

16

NAHH002SB

 

195/16

283/4

183/16

16

NAHH003SB

 

22_/16

28J/4

2113/16

16

NAHH010SB

 

243/4

283/4

239/16

161/4

Subbase

for

Coil Cabinets

 

 

 

 

NAHH004SB

 

1511/16

209/16

149/16

161/4

NAHH005SB

 

195/16

209/16

183/16

161/4

NAHH006SB

 

23

209/16

2113/16

161/4

NAHH009SB

 

2411/15

209/15

239/15

16

Outside Dimension

 

 

 

 

_* Base Spacer Side To Side

 

 

 

 

3.Set the base over the opening in the floor, centering it over the opening. Fasten the base to the floor with screws or nails. See Figure 38, Figure 39 and Figure 40.

4.Drop the plenum through the opening in the base. The flange of the plenum should rest on top of the subbase.

Opening

In Floor

Opening

In Base

Typical

Plenum

For Plenum

Dimensions

 

 

M

N

P

R

S

T

161/4

145/8

15

13112

15

131/2

161/4

181/4

15

17118

15

171/8

161/4

21//8

15

193/4

15

19_/4

161/4

235/8

15

221/2

15

221/2

161/4

145/8

15

131/2

15

131/2

161/4

181/4

15

171/8

15

171/8

161/4

21//8

15

193/4

15

19_/4

161/4

235/8

15

221/2

15

221/2

iiii!iiiiii;iiiiiiiill¸iiiiiiiiiiii;illlllllill_ll!ii!!!!!!!!lllll!ll_iilllll_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_ll__

i!i!i! i iiiiiiiCoiliiiiiiCabientiiiiiiiiiiSubbaseiiiiii;

Combustible

5.Position furnace or coil cabinet and furnace on subbase so it aligns between the locating tabs.

Furnace Subbase

T S

Combustible

FloorBase

Hj

25-20-46

FloorBase

J

25-20-46b

A 4 114" Minimum clearance ffomback of hole to wall or other obstruction.

iiiiiiiiiiiiiiiiiiiiiiiiiilill!! i!iiii¸i!¸I¸iil ;ii;iiiiiiiiiiiiiiiiiiiil;ili!iiiii

.... Setting the Subbase

Furnac_J" __

,g2t2,;at i lof

Floor Base

oo ,oor

_/'_

Plenum

25-20-46a

Wood Screw

This subbase for combustible floors has been designed so that the height of the subbase raises the downflow coil off the floor to allow

easy installation of the condensate drain. See Figure 41.

440O1102004

E_

Page 37
Image 37
Sears N9MP2080F16B1, N9MP2050B12B1, N9MP2075B12B1 SubbasesforCombustibleFloorsDimensions, FloorDimensions, Furnace Subbase