MANIFOLDPRESSUREAND ORIFICE SIZE FOR HIGHALTITUDEAPPLICATIONS

iiiiiiii_ ii_!!!!!!! i

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

GAS MANIFOLD

PRESSURE

(" w.c.)

 

 

 

 

 

 

..............................................................

FOR THE 50,000, 75,000, 100,000 and 125,000 BTUH MODELS

 

 

 

 

HEATING

 

 

 

 

MEAN

ELEVATION FEET ABOVE SEA LEVEL

 

 

 

 

0 to

2001 to

3001

to

4001 to

5001 to

6001 to

7001 to

VALUE

2000

3000

4000

 

5000

 

6000

7000

8000

at ALTITUDE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BTU/CU. FT,

Orifice

Manifold

Orifice

Manifold

Orifice

Manifold

Orifice Manifold Orifice Manifold Orifice

Manifold

Orifice

Manifold

 

No.

Pressure No.

Pressure No.

Pressure

No.

Pressure

No.

Pressure

No.

Pressure No.

Pressure

700

 

 

 

 

 

 

 

 

 

 

 

 

41

3.7

725

 

 

 

 

 

 

 

 

 

 

41

3.7

41

3.4

750

 

 

 

 

 

 

 

 

 

 

41

3.5

42

3.6

775

 

 

 

 

 

 

 

 

41

3.6

42

3.6

42

3.3

800

 

 

 

 

 

 

41

3.6

42

3,7

42

3,4

42

3.1

825

 

 

 

 

41

3.7

41

3.4

42

3.5

42

3.2

42

2.9

850

 

 

 

 

41

3.5

42

3.6

42

3,3

42

3,0

42

2.8

875

 

 

41

3.6

42

3.6

42

3.4

42

3.1

42

2.8

42

2.6

900

 

 

42

3,7

42

3,4

42

3.2

42

2.9

42

2,7

42

2.5

925

41

3.7

42

3,5

42

3,3

42

3.0

42

2,8

42

2,5

42

2.3

950

41

3.5

42

3.3

42

3.1

42

2.9

42

2,6

42

2.4

43

2.7

975

42

3.7

42

3,2

42

2,9

42

2.7

42

2,5

42

2,3

43

2.6

1000

42

3.5

42

3.0

42

2.8

42

2.6

42

2.4

43

2.7

43

2.4

1050

42

3.2

42

2.7

42

2,5

42

2.3

43

2.6

 

 

 

 

1100

42

2.9

42

2.5

42

2.3

43

2.6

 

 

 

 

 

 

NOTE: Natural gas data is based on 0.60 specific gravity. For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1-2002/NFPA 54-2002 or National Standard of Canada, Natural Gas And Propane Installation Code CSA B149.1-00.

Ta_i

 

CPG or PROPANE

GAS MANIFOLD PRESSURE (" w.c.)

 

 

................................................................................................................

FOR THE 50,000, 75,000, 100,000 and 125,000 BTUH MODELS

 

 

HEATING

VALUE

 

 

 

MEAN ELEVATION

FEET ABOVE

SEA LEVEL

 

 

at ALTITUDE

0 to

2001

to

3001 to

4001 to

5001 to

6001 to

7001 to

BTU/CU,

FT.

2000

3000

4000

5000

6000

7000

8000

2500

10.0

10.0

 

9.0

10.0

9.4

8.5

10.0

Orifice

Size

#54

#54

 

#54

#55

#55

#55

 

NOTE: Propane data is based on 1.53 specific gravity. For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1-2002/N FPA 54-2002 or National Standard Of Canada, Natural Gas And Propane Installation Code CSA B149.1-00.

 

NATURAL

GAS MANIFOLD

PRESSURE

(" w.c.)

 

 

 

 

 

 

..............................................................

FOR THE 80,000 BTUH MODELS

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

 

MEAN

ELEVATION FEET ABOVE SEA LEVEL

 

 

 

 

0 to

2001 to

3001

to

4001 to

5001 to

6001 to

7001 to

VALUE

2000

3000

4000

 

5000

 

6000

7000

8000

at ALTITUDE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BTU/CU. FT.

Orifice

Manifold

Orifice

Manifold

Orifice

Manifold

Orifice Manifold Orifice Manifold Orifice

Manifold

Orifice

Manifold

 

No.

Pressure No.

Pressure No.

Pressure

No.

Pressure

No.

Pressure

No.

Pressure No.

Pressure

700

 

 

 

 

 

 

 

 

 

 

 

 

44

3.7

725

 

 

 

 

 

 

 

 

 

 

44

3.7

44

3.4

750

 

 

 

 

 

 

 

 

 

 

44

3,5

44

3.2

775

 

 

 

 

 

 

 

 

44

3.5

44

3.2

44

3.0

800

 

 

 

 

 

 

44

3.6

44

3.3

44

3.0

44

2.8

825

 

 

 

 

44

3,7

44

3.4

44

3,1

44

2,9

44

2.6

850

 

 

 

 

44

3.5

44

3.2

44

2,9

44

2.7

44

2.5

875

 

 

44

3,5

44

3,3

44

3.0

44

2.8

44

2,5

44

2.3

900

 

 

44

3.3

44

3.1

44

2.8

44

2.6

44

2.4

45

2.7

925

44

3.7

44

3,2

44

2,9

44

2.7

44

2.5

44

2,3

45

2.5

950

44

3.5

44

3,0

44

2,8

44

2.6

44

2,4

45

2.6

45

2.4

975

44

3.3

44

2,8

44

2.6

44

2.4

45

2.7

45

2.5

45

2.3

1000

44

3.2

44

2,7

44

2,5

44

2.3

45

2.6

45

2.4

46

2.3

1050

44

2.9

44

2.5

44

2.3

45

2.5

45

2.3

 

 

 

 

1100

44

2.6

45

2.7

45

2.5

45

2.3

 

 

 

 

 

 

NOTE: Natural gas data is based on 0.60 specific gravity. For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1-2002/NFPA 54-2002 or National Standard of Canada, Natural Gas And Propane Installation Code CSA B149.1-00.

440 01 1020 04