ASSEMBLY
16.To check the oil level, tilt the cutter bar up 90 degrees and remove Plug(L) . Add SAE EP90 gear lube, or equivalent, at opening until oil flows from opening . Reinstall plug. Use thread sealant on plug threads. (See Figure 14 & 15).
The following approximate amounts of SAE EP90 gear lubricant, or equivalent, are required:
Model DM82 | 2.4 Quarts |
Model DM95 | 3.1 Quarts |
Model DM112 | 3.8 Quarts |
Model DM124 | 4.5 Quarts |
The gearbox and the cutter bar are lubricated by separate oil supplies.
Figure 14 | Figure 15 |
|
17.To check gearbox oil level remove fill plug (M)(See Figure 16). With gearbox and bar, level with the ground, oil should be at level line on dip stick. Fill with SAE EP90 gear lubricant if necessary. Requires 3/4 quart to fill.
| Figure 16 |
DM | Assembly Section |