Servis-Rhino DM95, DM82, DM124, DM112 Lubrication Chart, Proper Torque For Fasteners, Maintenance

Models: DM112 DM95 DM124 DM82

1 106
Download 106 pages 48.01 Kb
Page 94
Image 94
Lubrication Chart

MAINTENANCE

Lubrication Chart

Location

Description

Lubrication Frequency

1

Front IID U-joint

After Every 8 Hours of Operation

2

Rear IID U-joint

After Every 8 Hours of Operation

3

IID Shaft Slip Joints

After Every 8 Hours of Operation

4

Gearboxes and Cutter Bar, Fill to respective Level

Check Level After Every 8 Hours

 

Plug w/SAE EP90 or Equivalent Gear Lube

of Operation

5

Main Frame Pivot Point

Daily

6

All Sliding Sections

After Every 8 Hours of Operation

7

All Pivots & Linkage

After Every 8 Hours of Operation

PROPER TORQUE FOR FASTENERS

Because of the severe operating conditions, correct bolt torque is very important. An improperly torqued bolt can be easily shaken loose or broken by the vibrations. When replacing bolts, always use the same grade of bolt as used originally. Use this chart as a guide to tightening all bolts. Torque values listed are for general use only.

NOTE: These values apply to fasteners as received from supplier, dry or when lubricated with normal engine oil. They do not apply if special graphited or molydisulphide greases or other extreme pressure lubricants are used. This applies to both UNF fine and UNC coarse threads.

RECOMMENDED TORQUE IN FOOT POUNDS UNLESS OTHERWISE STATED IN THE MANUAL *

FIGURE 18

*

DM 07-02

Maintenance Section 5-6

 

© 2004 Alamo Group Inc.