Sharp AR-157E Close the side cover by pressing the round projections near, out and the start

Models: AR-157E AR-153E

1 121
Download 121 pages 9.52 Kb
Page 35
Image 35
Close the side cover by pressing the round projections near

A:Misfeed in the paper feed area

1Gently remove the misfed paper from the paper feed area as shown in the illustration. When the misfeed (the side cover open button. The misfeed ( ) indicator will go ) indicator blinks and the misfed paper is not seen from the paper feed area, pull out the paper tray and remove the misfed paper. If the paper cannot be removed, proceed to "B: Misfeed in the fusing area".

The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or other injury.

• Do not touch the photoconductive drum (green portion) when removing the misfed paper. Doing so may cause smudges on copies.

If the paper has been fed through the multi-bypass tray, do not remove the misfed paper through the multi-bypass tray. Toner on the paper may stain the paper transport area, resulting in smudges on copies.

2

 

6

Close the side cover by pressing the round projections near

 

the side cover open button. The misfeed ( ) indicator will go

 

out and the start (

) indicator will light up.

B: Misfeed in the fusing area

1

Lower the fusing unit release

 

lever.

Fusing unit release lever

33

Page 35
Image 35
Sharp AR-157E, AR-153E Close the side cover by pressing the round projections near, out and the start, lever