Image 90

Regarding the Lamp

Removing and Install- ing the Lamp Unit

Info

Be sure to remove the lamp unit by the handle. Be sure not to touch the glass surface of the lamp unit or the inside of the projector.

To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.

Do not loosen other screws except for the lamp unit cover and lamp unit.

(Only the silver screws are loosened).

Please refer to the installation manual included with the lamp unit.

1 Press on the projector to turn off the power.

Wait until the cooling fan stops.

Warning!

Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn or injury.

2 Disconnect the power cord.

Unplug the power cord from the AC socket.

Leave the lamp until it has fully cooled down (about 1 hour).

3 Change the air filter.

Change the air filter whenever you in- stall the lamp unit (see pages 81 and 82).

4 Remove the lamp unit cover.

Loosen the user service screw that secures the lamp unit cover. Then open the cover in the direction of the arrow.

Lamp

BQC-XGC50X//1

unit

 

Power (OFF) button

AC socket

User service screw