Shindaiwa DGW310MC, DGW310DMC owner manual Long-Term Storage, Change Coolant/Water

Models: DGW310MC DGW310DMC

1 42
Download 42 pages 723 b
Page 38
Image 38
1 Openthe top door.
2 Remove the radiator cap.
3 Remove the water drain plug.
4 After draining all the water, reinstall the water drain plug.

(6) Change Coolant/Water

Change

At 2000 hrs or 2 yrs

Total capacity: 3L (including Sub Tank: 0.6L

)>

Top Door

Radiator Cap

Water Inlet

Caution

Sub Tank

 

 

 

Change the packing whenever changing

 

 

coolant/water.

 

 

Packing Part No.: 6C090 58961 (Kubota)

 

5 Replace all the water in the sub tank.

 

6 Fill water to Max Level (to the water inlet)

 

7 Reinstall the radiator cap.

Coolant Drain Plug

8 Close the top door.

 

Caution

 

 

 

 

After supplying water, keep the engine drive for

 

a while to check no water leakage and then stop the engine

12. Long-Term Storage

Danger: Electric Shock

.When performing check and maintenance, always stop the engine

Caution: Injuries

When performing check and maintenance always stop the engine

Caution: Fire/Burns

Keep the equipment far away from fire.

Do not touch the engine and muffler during operation or immediately after stopping the equipment for the temperature reaches extremely high.

36