7-2 Stopping

1. Turn the breaker to OFF .

2 .Turn the slow-down switch to ON .

3. Keep the engine (cool down) for about 5 minutes.

4. Turn the starter switch to STOP .

5. After the engine stops, turn the fuel lever to CLOSE .

Caution

When the engine will not stop in spite of turning the starter switch to STOP, turn the fuel lever to CLOSE,

 

 

 

 

 

then the engine will stop in a few minutes. In this case, be sure to consult with our authorized distributor

 

 

 

 

 

or our service section and ask to repair.

 

 

8.Welding

 

 

Operation

 

 

8-1. Selection – Welding Cable

Select the cable in proper gauge, based on the allowable amperage and the length, per the table shown below.

The welding capacity is to reduce if the small gauge or long cable is used.

Caution

Welding cables should be used unstrained. When the welding cable are used in swirl, the welding

capacity is to reduce

 

 

 

 

 

 

 

 

 

 

 

 

 

Size of Cable

Unit

 

mm2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

 

 

 

 

 

 

 

 

 

 

Length

20m

30m

 

40m

 

60m

 

80m

100m

 

 

 

 

 

 

 

 

 

 

Current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300A

30

38

 

50

 

80

 

100

125

 

 

 

 

 

 

 

 

 

 

 

 

250A

22

30

 

38

 

60

 

80

100

 

 

 

 

 

 

 

 

 

 

 

 

200A

22

30

 

30

 

50

60

80

 

 

 

 

 

 

 

 

 

 

150A

22

22

 

22

 

38

 

50

60

 

 

 

 

 

 

 

 

 

 

 

 

100A

22

22

 

22

 

30

 

30

38

 

 

 

 

 

 

 

 

 

 

 

 

22