6-2. Coolant and Water

Danger: Injuries

Close all doors and locks during operating equipment to avoid injuries by accidental touch cooling fan or fan belt.

Danger: Burns

Do not open the radiator cap while operating the equipment or immediately after stopping the equipment to avoid sustaining burn from hot vapor.

￿Caution: Burns

Do not touch the engine or muffler during operation or immediately after stopping the equipment for the temperature can reach extremely high.

Check to see if the coolant/water level is between

FULL and LOW in the sub tank.

If it is below

 

 

 

 

LOW level, fill he tank and the radiator accordingly.

 

 

 

 

 

 

 

(1) Filling the sub tank

 

 

 

 

 

1.

Remove the sub tank cap.

 

 

 

Cap

2.

Fill up the sub tank to

FULL

level.

 

 

 

3. Install the cap again.

 

 

 

 

Sub Tank

 

 

 

 

 

 

 

(2) Filling the radiator

 

 

 

 

 

1.

Open the top plate.

 

 

 

 

 

2.

Remove the radiator cap.

 

 

 

 

3.

Fill the radiator up to the top/

 

 

 

 

4. Install the cap again and tighten.

 

 

 

5.

Close the top plate.

 

 

Sub tank

Caution

Use LongLife Coolant to prevent from freeze and rust. (30% mixture LLC is filled when shipped out from factory)