Sample Configurations

Device Configuration for Single Line

5.3Device Configuration for Single Line

To provide a better overview, the items in the following table are highlighted gray. The column on the right contains a reference to the WEB interface where the parameters are manually en- tered. The following example shows the device configuration for an optiPoint 410 economy, configured as a single line phone.

Device configuration file op410eco_conf0001e322e68c.xml

 

Element or description

 

WBM

 

 

 

 

 

<?xml version = "1.0" encoding = "utf-8" ?>

 

 

 

- <Message>

 

 

 

<Action>WriteItems</Action>

 

 

 

- <ItemList>

 

 

 

<!--

Caution!! Empty attribute entries will delete associated data.

-->

 

 

 

 

 

 

 

<!--

If you do not want to configure an attribute,

-->

 

 

 

 

 

 

 

<!--

the element must be deleted in the XML file.

-->

 

 

 

 

 

 

 

<!--

The device configuration version attribute should be the first element.

-->

 

 

 

 

 

 

 

<!--

The value should have the format "2005.01 12:00 GMT" and be

-->

 

 

 

 

 

 

 

<!--

assigned to the attribute name with the keyword "device-config-version".

-->

 

 

 

 

 

 

 

<!--

The expression should be entered between the <Item ...> start tag and the

-->

 

 

 

 

 

 

 

<!--

</Item> end tag.

-->

 

 

 

 

 

<!-- For example, <Item name = "device-config-version">2005.07.06 08:40 GMT</Item>

 

 

-->

 

 

 

 

 

 

 

 

<!--Make sure you enter spaces before and after the "=" sign -->

 

 

 

 

 

 

 

<Item name = "device-config-version">2005.07.06 08:40 GMT</Item>

 

 

 

- <!-- Phone number

-->

 

 

 

 

 

 

<Item name = "e-164">3015553006</Item>

 

! page 4-5

 

- <!-- Terminal Name

-->

 

 

 

 

 

 

<Item name = "sip-name">John Doe jr.</Item>

 

! page 4-5

 

- <!-- Register by name (true or false)

-->

 

 

 

 

 

 

<Item name = "register-by-name">false</Item>

 

! page 4-5

 

<!-- SIP realm

-->

 

 

 

 

 

 

<Item name = "realm">as.broadworks.net</Item>

 

! page 4-5

 

<!--SIP user ID

-->

 

 

 

 

 

 

<Item name = "sip-user-id">3015553006</Item>

 

! page 4-5

 

<!-- SIP password

-->

 

 

 

 

 

 

<Item name = "sip-pwd">dfg04go6t</Item>

 

! page 4-17

 

 

 

 

A31003-J4260-M101-2-76A9, 03-2007

5-11

XML Configuration Management, Administrator Manual

Page 148
Image 148
Siemens 410 S V6.0 manual Device Configuration for Single Line, Device configuration file op410ecoconf0001e322e68c.xml