Siemens 410 S V6.0, 420 S V6.0 SIP session timer value, Registration timer value, SIP realm, 3-15

Models: 420 S V6.0

1 154
Download 154 pages 24.1 Kb
Page 38
Image 38
3.3.3.19SIP session timer value

XML Overview

Administration Tags

3.3.3.19SIP session timer value

Parameter

session-duration

WEB

 

 

 

Index

 

 

 

 

Value

1 to 3600

Session duration in seconds;

 

 

default: 3600

 

 

 

Example

<Item name="session-duration">3600</Item>

 

 

 

 

Notes

e164

 

 

 

 

3.3.3.20Registration timer value

Parameter

reg-ttl

WEB

 

 

 

Index

 

 

 

 

Value

1 to 3600

Registration time (in seconds) be-

 

 

fore reregistration is necessary;

 

 

default: 3600

 

 

 

Example

<Item name="regttl">3600</Item>

 

 

 

 

Notes

e164

 

 

 

 

3.3.3.21SIP realm

Parameter

realm

WEB

 

 

 

Index

 

 

 

 

Value

ABCDabcd1234

String (max. 93; Alphanumeric)

 

 

 

Example

<Item name="realm">as.broadworks.net</Item>

 

 

 

Notes

e164

 

 

 

 

A31003-J4260-M101-2-76A9, 03-2007

3-15

XML Configuration Management, Administrator Manual

Page 38
Image 38