3.3.13.16Line – Shared type

Parameter

line-shared-type

WEB

 

 

 

Index

1 to 18

Normal function keys 1 to 18, opti-

 

 

Point 410 advance

 

 

 

Index

101 to 116

Normal function keys 1 to 16, key

 

 

module 1

Index

201 to 216

Normal function keys 1 to 16, key

 

 

module 2

Index

301 to 313

Normal function keys 1 to 13, self

 

 

labeling key module 1

Index

401 to 413

Normal function keys 1 to 13, self

 

 

labeling key module 2

Value

0, 1, 2

Multiline type (0 = shared, 1 = pri-

 

 

vate, 2 = unknown); Integer

 

 

 

Example

<Item name="line-shared-type" Index="6">0</Item>

 

 

Notes

Only possible if the key has been configured with "line"

 

 

 

3.3.13.17Line – Hot line

Parameter

line-hld-active

 

WEB

 

 

 

 

Index

1 to 18

 

Normal function keys 1 to 18, opti-

 

 

 

Point 410 advance

 

 

 

 

Index

101 to 116

 

Normal function keys 1 to 16, key

 

 

 

module 1

Index

201 to 216

 

Normal function keys 1 to 16, key

 

 

 

module 2

Index

301 to 313

 

Normal function keys 1 to 13, self

 

 

 

labeling key module 1

Index

401 to 413

 

Normal function keys 1 to 13, self

 

 

 

labeling key module 2

Value

true, false

 

Hot-Line on or off

 

 

 

Example

<Item name="line-hld-active" Index="6">true</Item>

 

 

Notes

Only possible if the key has been configured with "line"

 

 

 

 

3-50

 

 

A31003-J4260-M101-2-76A9, 03-2007

 

XML Configuration Management, Administrator Manual

Page 73
Image 73
Siemens 420 S V6.0, 410 S V6.0 manual Line - Shared type, Line - Hot line, 3-50, XML Overview, Administration Tags