Siemens 420 S V6.0 manual QoS Data Collection, Send QDC Traps to QCU, QDC Address, QDC Port, 3-74

Models: 420 S V6.0

1 154
Download 154 pages 24.1 Kb
Page 97
Image 97

XML Overview

Administration Tags

3.3.21QoS Data Collection

3.3.21.1Send QDC Traps to QCU

Parameter

qdc-qcu-active

WEB

 

 

 

Index

 

 

 

 

Value

true, false

Option on or off

 

 

 

Example

<Item name="qdc-qcu-active">true</Item>

 

 

 

 

Notes

 

 

 

 

 

3.3.21.2QDC Address

Parameter

qdc-collection-unit-addr

WEB

 

 

 

Index

 

 

 

 

Value

0.0.0.0

IP address

 

 

 

Example

<Item name="qdc-collection-unit-addr">172.16.127.2</Item>

 

 

 

Notes

 

 

 

 

 

3.3.21.3QDC Port

Parameter

qdc-collection-unit-port

WEB

 

 

 

Index

 

 

 

 

Value

0 to 65535

Port address; Integer

 

 

 

Example

<Item name="qdc-collection-unit-port">162</Item>

 

 

 

Notes

 

 

 

 

 

3-74

A31003-J4260-M101-2-76A9, 03-2007

XML Configuration Management, Administrator Manual

Page 97
Image 97