Technical Specifications

Permitted Cable Lengths

 

 

FO cable length between two OSMs

For OSM ITP62, OSM ITP53, OSM

 

TP62, OSM TP22:

 

0-3000 m (62.5/125 m glass fiber; 1

 

dB/km at 1300 nm; 600 MHz*km; 6 dB

 

max. permitted FO cable attenuation at 3

 

dB link power margin)

 

0-3000 m (50/125 m glass fiber; 1

 

dB/km at 1300 nm; 600 MHz*km; 6 dB

 

max. permitted FO cable attenuation at 3

 

dB link power margin)

 

For OSM ITP62-LD:

 

0-26000 m (10/125 m single mode

 

fiber; 0,5 dB/km at 1300 nm; 13 dB max.

 

permitted FO cable attenuation at 2 dB

 

link power margin)

ITP cable length

0-100 m

TP cable length

0-10 m with TP cord

 

up to 100 m total length when using the

 

FastConnect cabling system

Length of the ITP XP Standard Cable

0-40 m

9/9 at standby-sync port

 

 

 

 

 

Cascading Depth

 

 

Bus/star structure

Any (only depending on signal

 

propagation time)

Redundant ring

50 (for reconfiguration time < 0.3 s)

 

 

 

Switching Properties of OSM/ESM

 

 

Number of learnable addresses

 

Up to 7000

Aging time

 

40s (default)

Latency

 

4 s (measured at 75% load between

 

 

two ports operating at 100 Mbps)

Switching procedure

 

Store and forward