Technical Specifications

Ports

 

Power loss at 24 V DC

20 W

 

 

Load on the signaling contact

DC 24 V / max. 100 mA safety extra-

 

low voltage (SELV)

Current consumption at rated voltage

1000 mA

Overcurrent protection at input

Non-replaceable fuse (1.6 A / 250 V /

 

slow)

Digital Inputs

Input voltage:

 

Rated voltage DC 24 V safety

 

extra-low voltage (SELV)

 

For state "1": +13 ...+30V

 

For state "0": –30 ... +3V

 

Max. input current: 8 mA

 

Max. cable length: 30 m

 

Inputs electrically isolated from

 

electronics.

Industrial Ethernet OSM/ESM

79

C79000-Z8976-C068-10

Page 83
Image 83
Siemens OSM, ESM technical specifications Technical Specifications