Interfaces, Displays and Operator Controls
Full duplex |
|
| Port LED |
|
|
| - Lit green: Port operating in full duplex |
Display |
|
| mode |
3 | 2 | 1 | - Not lit: Port operating in half duplex mode |
| |||
LED off | LED on | LED off |
|
Note |
|
|
|
LED 3 exists only on devices with digital |
| ||
inputs. |
|
|
|
|
|
|
|
Fault mask |
|
| The fault mask indicates whether the ports |
|
|
| and the power supplies are monitored with |
Display |
|
| the signaling contact. |
|
| Port LED | |
|
|
| |
3 | 2 | 1 | - Lit green: Port is monitored; in other |
words, if the port does not have a valid | |||
|
|
| connection (for example cable not |
LED off | LED on | LED on | plugged in or attached device turned off), |
the signaling contact is triggered. | |||
|
|
| - Not lit: The port is not monitored; in other |
Note |
|
| words, an invalid or valid connection at |
LED 3 exists only on devices with digital | the port does not trigger the signaling | ||
inputs. |
|
| contact. |
|
|
| The fault mask can be set again with the |
|
|
| button on the front panel of the OSM (see |
|
|
| 4.2.4.2) |
Digital inputs |
|
| Port LED |
|
|
| - Lit green: The logical state "1" is applied |
Display |
|
| to the corresponding digital input. This |
|
| requires an input voltage of + 13 V DC to | |
|
|
| |
|
|
| + 30 V DC. |
3 | 2 | 1 | - Not lit: The logical state "0" is applied to |
|
|
| the corresponding digital input. This |
LED on | LED off | LED off | requires an input voltage of + |
to + 3 V DC. | |||
Note |
|
|
|
LED 3 exists only on devices with digital |
| ||
inputs. |
|
|
|
|
|
|
|
The basic status "Port Status" of the display is adopted automatically after turning on the device. The device also switches automatically to this display status when the "Select/Set" button is pressed for more than a minute.
Industrial Ethernet OSM/ESM | 59 |