108
Now, set the CPU board’s telemetry digital level set pot to 2.5 KHz deviation on
the port 0 transmitter output.
Step 7 – Turn off the built in test tone generator.
*C220
Step 8 – Set local telemetry level on each transmitter.
Now that the master telemetry bus is set, step through each RCB to set the
telemetry level that is unique to each port.
Set the receiving service monitor to the port 0 transmitter frequency.
*C220
Once the telemetry pots are set for max system deviation, you can adjust the actual
telemetry level under software control. Each telemetry type has an associated level
parameter. For example, this will allow you to set the CW ID to 20% of system deviation
while the function complete and dialtone telemetry are set for 60% of system deviation.
Basic level sets are now done!