5. Do not touch electrode needle with finger or metal tool directly. It may cause injury.

If electrode needle or cartridge is it may stick to the fingers, damaged by tools, it will not only interfere the specification function and performance but also may cause operation failure or accident.

Caution for High Voltage

Do not touch the electrode needle. High voltage is supplied.

If foreign substances are inserted or persons come in contact with it, they might get injured when trying to avoid the electric shock or instantaneous lightning stroke.

6.Do not attach tape or seal on the product body.

If conductive adhesive and reflective paint is contained in the tape or seal, dielectric phenomenon will occur due to the produced ion and it may lead to the electrostatic charge and electric leakage.

7.Be sure to install and adjust after power supply is stopped.

!CAUTION

1.Install IZS31 series with keeping distance from the wall etc. as shown in the figure below.

The generated ion might not reach the target effectively and efficiency decrease, where there is wall etc. inside the area shown in the figure below.

200mm

200mm

150mm

150mm

 

 

2.Be sure to check the effect of static charge elimination after installation.

The effect of static charge elimination largely varies depending on the ambient installation conditions and operation conditions. After installation, be sure to check the effect of static charge elimination.

Wiring and piping

!WARNING

1.Check that power supply capacity is enough and voltage is in specification before piping.

2.When selecting power supply,always use a UL-Listed power supply that either provides Class2 output as defined in the National Electrical Code,or that has been evaluated as a Limited Power Source as defined in UL60950.

3.To maintain the product performance, Apply Ground at a resistance not exceeding 100 Ωto prevent electrical shock in accordance with instructions on this operation manual.

4.Be sure to cut off power supply at wiring (including connector plug-in/out) .

5.Use a dedicated cable with a sensor to connect the ionizer and a feed back sensor or an auto balance sensor, and do not disassemble and/or modify the cable for the sensor.

6.Turn on the power after examining wiring and a surrounding situation enough, and confirming safety.

7.Do not connect and disconnect connectors while supplying the power. Ionizer might be broken and cause malfunction.

8.Installation with high-voltage line and power line in the same wiring route may cause malfunction by noise. Install separately with them.

4