4-2. Pulse DC mode
Model NuFile00

4-2. Pulse DC mode

1. Selection of the bar length

Select an appropriate length that is suitable for the work size, static charge elimination characteristics and static charge elimination range.

2. Installation of the ionizer

Keep the distance between the ionizer and charged object within 50 to 2000mm. When the auto balance sensor is used, the distance should be ranged from 100 to 2000mm. When the ionizer is used outside of the operating conditions, it might not operate properly. In that case, be sure to check if the ionizer will operate properly.

3. Installation of the sensor

Install the auto balance sensor to adjust the ion balance.

Horizontally place the auto balance sensor under the ionizer, and install the sensor on the same level with a workpiece as much as possible.

When he auto balance sensor is connected, the balance adjustment trimmer will be invalid.

4. Setting of the maintenance level selecting switch

[manual operation] or [auto operation] can be selected when the ion balance needs to be adjusted with the auto balance sensor.

 

Description

Switch setting

Manual

Ion balance is adjusted when the maintenance

MANUAL

operation

start-up signal is input or when the power

 

 

supply of the Ionizer is applied.

 

AUTO MANUAL

The ion-balance adjustment values are

 

 

retained per ion-production frequency. When

 

 

the ion-production frequency is changed, adjust

 

 

the ion balance.

 

 

Once the ion-balance adjustment is completed,

 

 

the ion balance adjustment will not be executed

 

 

unless the next maintenance start-up signal is

 

 

input. Therefore, the auto balance sensor can

 

 

be removed.

 

Auto operation

Ion-balance is continuously adjusted.

AUTO

 

Once the auto balance sensor is removed,

 

 

manually adjust the ion-balance with a balance

 

 

adjustment trimmer.

 

*Set the switch in line with the detection level of the dirt on the electrode needle.

When the auto balance sensor is not used, change the switch setting to AUTO, and manually adjust the ion-balance with a balance adjustment trimmer.

Balance aadjustment trimmer

Set the level for detecting the dirt on the electrode needle.

Select the level from HHigh, MMiddleor LLow. The dirt on the electrode needle cannot be detected with other levels.

HHigh) ・・・ The level that doesn’t affect the static charge eliminating time (Even a small amount of dirt can be detected).

MMiddle) ・・The level that can notify the maintenance just before the static charge elimination time becomes slow.

LLow) ・・・ The level that the static charge elimination time becomes slower than the one in the initial state.

The dirt detection will begin once the maintenance start-up signal is input.

If H, M and L levels are set, ion balance adjustment is executed after the dirt on the electrode needle is detected.