![](/images/new-backgrounds/1110674/110674269x1.webp)
Note: +++ is not proceeded by AT nor does it require a carriage return (enter). There must be an idle time (set by S50) on the serial port before and after this command.
Note: A/ is not proceeded by AT.
Rev 3.0B Feb.08
Configuration Commands
Misc (Miscellaneous)
The commands of the “Misc” group are a variety of commands that don’t directly fit in other categories.
Figure 1-5: AceManager : Misc
+++
AT Escape sequence. If the PinPoint X is in a data mode (any mode other than PassThru), this command causes the modem to re‐enter AT command mode. The “+” is ASCII 0x2B.+++ is not available in AceManager.
Tip: DAE=1 disables the +++ command.
A/
Re‐execute last command. A/ is not used in AceManager.
A
Manually answer an incoming connection. A is not used in AceManager.
D[method][d.d.d.d][/ppppp] or D[method][@name][/ ppppp]
Dial a connection to a remote IP and Port using method. Cannot be configured in AceManager.
•method=P : Establish a UDP connection
•method=T : Establish a TCP connection
•method=N : Establish a Telnet connection
122