Place the internal locking nut over the end of the interconnection cable, then attach connectors B and C to the connectors (as shown in the figure).

The broken line shows the route for the interconnection cable.

Attach connector D to one of the screws close by to provide an Earth (as shown in the figure).

The wiring details for the connector ends (B, C, and D) are as follows:

2 kW interconnection cable (NS003101) connector ends

Pin

Color/Name

AWG size

B

C

D

1

Green (big)

#12

 

1

 

 

 

 

 

 

 

2

Yellow (big)

#12

 

2

 

 

 

 

 

 

 

3

Green (thin)

#24

7

 

 

 

 

 

 

 

 

4

Clear Coax signal

#24

4

 

 

 

 

 

 

 

 

5

Drain wire for 4

#24

5

 

 

 

 

 

 

 

 

6

Drain wire for 7

#24

3

 

 

 

 

 

 

 

 

7

Black Coax signal

#24

2

 

 

 

 

 

 

 

 

8

White

#24

6

 

 

 

 

 

 

 

 

Page 26