9 | Yellow | #24 | 1 |
|
|
|
|
|
|
|
|
10 | White (big) | #12 |
| 3 |
|
|
|
|
|
|
|
Shell | Braid shield |
|
|
| X |
|
|
|
|
|
|
6.2Run the 2 kW interconnection cable (NS003100/NS003101) to the radar processor
Run the 2 kW interconnection cable (NS003100/NS003101) from the scanner to the radar processor.
Push the round connector (A) of the 2 kW interconnection cable into the scanner connection on the radar processor and tighten the locking nut.
The interconnection cable pin details are provided here for information, in case the connector needs to be removed to feed the cable, or in case the cable needs to be shortened.
The front view of the 2 kW interconnection cable is shown above.
2 kW interconnection cable pin details
Pin | Color/Name | Signal name | AWG size |
1 | Green (big) | Power | #12 |
|
|
|
|
2 | Yellow (big) | Power GND | #12 |
|
|
|
|
3 | Green (thin) | Pulse width | #24 |
|
|
|
|
4 | Clear Coax signal | Video | #24 |
|
|
|
|
5 | Drain wire for 4 | Video GND | #24 |
|
|
|
|
6 | Drain wire for 7 | Trig GND | #24 |
|
|
|
|
7 | Black Coax signal | Trig/STC | #24 |
|
|
|
|
8 | White | BZ Tune to scanner | #24 |
|
|
|
|
9 | Yellow | Tune from scanner | #24 |
|
|
|
|
10 | White (big) | No connection | #12 |
|
|
|
|
Shell | Braid shield |
|
|
|
|
|
|