9

Yellow

#24

1

 

 

 

 

 

 

 

 

10

White (big)

#12

 

3

 

 

 

 

 

 

 

Shell

Braid shield

 

 

 

X

 

 

 

 

 

 

6.2Run the 2 kW interconnection cable (NS003100/NS003101) to the radar processor

Run the 2 kW interconnection cable (NS003100/NS003101) from the scanner to the radar processor.

Push the round connector (A) of the 2 kW interconnection cable into the scanner connection on the radar processor and tighten the locking nut.

The interconnection cable pin details are provided here for information, in case the connector needs to be removed to feed the cable, or in case the cable needs to be shortened.

The front view of the 2 kW interconnection cable is shown above.

2 kW interconnection cable pin details

Pin

Color/Name

Signal name

AWG size

1

Green (big)

Power

#12

 

 

 

 

2

Yellow (big)

Power GND

#12

 

 

 

 

3

Green (thin)

Pulse width

#24

 

 

 

 

4

Clear Coax signal

Video

#24

 

 

 

 

5

Drain wire for 4

Video GND

#24

 

 

 

 

6

Drain wire for 7

Trig GND

#24

 

 

 

 

7

Black Coax signal

Trig/STC

#24

 

 

 

 

8

White

BZ Tune to scanner

#24

 

 

 

 

9

Yellow

Tune from scanner

#24

 

 

 

 

10

White (big)

No connection

#12

 

 

 

 

Shell

Braid shield

 

 

 

 

 

 

Page 27
Image 27