Skil 3310 manual Motor Specifications and Electrical Requirements, General Specifications

Models: 3310

1 80
Download 80 pages 32.23 Kb
Page 6
Image 6
! WARNING

SM 2610008289 02-10:3310 Table Saw 2/2/10 8:38 AM Page 6

Motor Specifications and Electrical Requirements

General Specifications

Voltage Rating

. . . . . . . . . . . . .120 V, 60 Hz

Amperage Rating . . .

. . . . . . . . . . . . . . . . . . . .15 A

No Load Speed

. . . . . . . . . . . . .No 5,000/min

Sawing capacity

. . .3" (7.62 cm) at 90 degrees

. . . . . . . . . . . . . . . . . .

2 1/2" (6.35 cm) at 45 degrees

. . . . . . . . . . . . . . . . . . . .

. . . . .1/2" (1.27 cm) with dado

Table size

. . . . . . . . . . . . . .18 7/8 x 26”

Double Insulated Tools

Double Insulation        is a design concept used in elec rict power tools which eliminates the need for the three wire grounded pow er cord and grounded power supply system. It is a recog nized and approved system by Underwriter’s Lab- oratories, CSA and Federal OSHA authorities.

IMPORTANT: Servicing of a tool with double insulation re- quires care and knowledge of the system and should be performed only by a qualified service technician.

WHEN SERVICING, USE ONLY IDENTICAL REPLACE- MENT PARTS.

POLARIZED PLUGS. If your tool is equipped with a po arl zedi plug (one blade is wider than the other), this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. To reduce the risk of electric shock, do not change the plug in any way.

Extension Cords

!

WARNING

Replace damaged cords immediately. Use

of damaged cords can shock, burn or elec-

 

 

trocute.

Always use proper extension cord. If an extension cord is necessary, a cord with adequate size con ductors should be used to prevent

excessive voltage drop, loss of power or over heating. The table shows the correct size to use, de pending on cord length and nameplate amperage rating of tool. If in doubt, use the next heavier gauge. Always use U.L. and CSA listed extension cords.

RECOMMENDED SIZES OF EXTENSION CORDS 120 VOLT ALTERNATING CURRENT TOOLS

Tool’s

Cord Size in A.W.G.

Wire Sizes in mm2

Ampere

 

 

 

 

 

 

 

 

Cord Length in Feet

Cord Length in Meters

Rating

 

25

50

100

150

15

30

60

120

3-6

18

16

16

14

.75

.75

1.5

2.5

6-8

18

16

14

12

.75

1.0

2.5

4.0

8-10

18

16

14

12

.75

1.0

2.5

4.0

10-12

16

16

14

12

1.0

2.5

4.0

12-16

14

12

 

 

 

 

 

 

 

 

 

NOTE: The smaller the gauge number, the heavier the cord.