WATER PIPING

 

Always follow good piping practices. Observe minimum 1"

 

clearance to combustibles around all uninsulated hot water

 

pipes or when openings around pipes are not protected by

 

non-combustible materials.

 

On a hot water boiler installed above radiation level, the boil-

 

er must be provided with a low water cutoff device at the time

 

of installation by the installer. (see Figure 15 for piping

 

arrangement)

 

1. Supply and Return

 

For tapping sizes see dimensions on page 2. Shut-off

 

valves are recommended.

 

2. Circulating Systems

 

Victory II boilers are equipped with a water circulating

 

pump mounted to the return water connection on the

 

boiler. This pump location is appropriate for most installa-

 

tions. It may be desired and proper to locate this pump to

 

the alternate pump location shown in Figure 15, especially

 

when applied to larger systems using high-head pumps.

 

When the pump is removed there is a 11/2" FPT tapping

Figure 11b.

that the return pipe may be attached to.

3. Air Control System

Diaphragm type compression tank is used to control sys- tem pressure. It must be installed at the boiler or between boiler and supply main pump(s).