Smeg A2PY-6 manual Room ventilation, Instructions for the Installer

Models: A2PY-6

1 38
Download 38 pages 52.93 Kb
Page 5
Image 5
2.2Room ventilation

Instructions for the Installer

Operation at 380-415V 3N: use a type H05RR-Ffive-wire cable (cable of 5 x 1.5 mm2).

Operation at 380-415V 2N: use a type H05RR-Ffour-wire cable (cable of 4 x 1.5 mm2).

Operation at 220-240V: use a type H05RR-Fthree-wire cable (cable of 3 x 2.5 mm2).

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

The manufacturer declines all responsibility for injury or damage caused by failure to comply with the above regulations or deriving from tampering with even just one part of the appliance.

2.2Room ventilation

The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 1989.

1.All rooms require an opening window or equivalent, and some rooms will require a permanent vent as well.

2.For room volumes up to 5 m3 an air vent of 100 cm2 is required.

3.If the room has a door that opens directly to the outside, and the room exceeds 1 m3 no air vent is required.

4.For room volumes between 5 m3 and 10 m3 an air vent of 50 cm2 is required.

5.If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should be consulted to determine the air vent requirements.

6.This appliance must not be installed in a bed sitting room of less than 20 m3 or in a bathroom or shower room.

Windows and permanent vents should therefore not be blocked or removed without first consulting a Corgi gas installer.

Failure to install appliances correctly is dangerous and could lead to prosecution.