Instructions for the Installer

3.2Burner and Nozzle Data Tables

Burner

Auxiliary

Semi rapid

Rapid

Ultra rapid

Burner

 

Nominal

 

 

 

 

 

 

 

 

 

 

 

 

 

heat

 

 

 

 

Bottled gas – G30/G31 30/37 mbar

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

By-pass

 

 

Reduced

 

Flow rate

 

Flow rate

 

 

 

diameter

 

mm

 

 

heat

 

g/h G30

 

g/h G31

 

 

 

1/100 mm

 

1/100

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.05

 

50

 

30

 

 

400

 

76

 

75

 

 

 

 

 

 

 

 

 

 

 

1.8

 

65

 

33

 

 

500

 

131

 

129

 

 

 

 

 

 

 

 

 

 

 

3

 

85

 

45

 

 

800

 

218

 

215

 

 

 

 

 

 

 

 

 

 

 

4.0

 

100

 

65

 

 

1600

 

290

 

286

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal

 

 

 

 

 

 

 

 

 

 

 

 

 

heat

 

 

 

 

 

Natural gas - G20 20 mbar

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

Auxiliary

 

1.05

 

72

 

 

 

 

 

 

Semi rapid

 

1.8

 

97

 

 

 

 

 

 

Rapid

 

3

 

115

 

 

 

 

 

 

Ultra rapid

 

4.0

 

135

 

Reduced heat capacity

(W)

400

500

800

1600

3.3Hob burner layout

BURNERS

1 Auxiliary

2 Semi rapid

3 Rapid

4 Ultra rapid

5 Ultra rapid

49

Page 8
Image 8
Smeg A2PY-6 manual Burner and Nozzle Data Tables, Hob burner layout, Burners