Instructions for the Installer

4. FINAL OPERATIONS

After changing the nozzles, put the pan stands, the burner caps and flame diffuser rings back in place.

After adjusting for use of a gas other than the gas used for testing the appliance, replace the gas setting label inside the storage compartment with the label for the new gas. The label is available from your nearest Authorised Service Centre.

4.1Adjusting the minimum setting for town gas and natural

gas

Light the burner and turn it to the minimum setting

. Remove the gas tap knob and adjust the regulator screw inside or beside the tap rod (depending on the model) until an even minimum flame is obtained. Put the knob back in place and check the stability of the burner flame (the flame must not go out when the knob is turned quickly from the maximum to the minimum setting). Repeat the operation on all the gas taps.

4.2Adjusting the minimum for bottled gas

The diameters of the bypasses for each individual burner are stated in point "3.2 Burner and nozzle characteristics table". When the adjustment is complete, re-seal the bypasses with paint or another similar material.

4.3 Positioning and levelling the appliance

After making the electrical and gas connections, level the appliance by means of its four adjustable feet.

50

Page 9
Image 9
Smeg A2PY-6 manual Final Operations, Adjusting the minimum setting for town gas and natural Gas