Smeg CS122-6 manual Electrical connection, This nameplate must never be removed

Models: CS122-6

1 37
Download 37 pages 45.23 Kb
Page 5
Image 5
2.2 Electrical connection

Instructions for the Installer

2.2 Electrical connection

Check that the voltage and size of the power supply line are as specified on the nameplate inside the storage compartment.

This nameplate must never be removed.

The plug on the end of the power supply cable and the wall socket must be of the same type (in compliance with the relevant national standards).

Check that the power supply line is properly earthed. The use of reductions, adapters or junctions is not recommended.

The appliance's power supply line must be fitted with an omnipolar breaking device with contact gap of at least 3 mm, located in an easily

accessible position close to the appliance itself.

The appliance has a terminal board on its rear. To access it, remove the back cover.

Make the electrical connection in accordance with the wiring diagram shown below.

Operation at 380-415V3N~:use a H05RR-F or H05RN-Ffive-wire cable (cable of 5 x 1.5 mm2).

Operation at 380-415V2N~:use a H05RR-F or H05RNF four-wire cable (cable of 4 x 2.5 mm2).

Operation at 220-240 V~: use a H05RR-F / H05RNF three-wire cable (cable of 3 x 6 mm2).

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

The manufacturer declines all responsibility for injury or damage caused by failure to comply with the above regulations or deriving from tampering with even just one part of the appliance.