1 Press the SCH button on the vectorscope.
The vectorscope switches to SCH mode.
2 Press the B channel button on the vectorscope.
This displays the black burst signal from the switcher.
3 Press the EXT button on the vectorscope.
This switches the vectorscope to external synchronization mode.
4 Adjust the phase synchronization control on the vectorscope so that the sync and subcarrier phases are close to the reference line.
Note
When component signals are used the subcarrier phase indicator does not appear.
8 Output the player 2 signal from the
Sync phase
Subcarrier phase | Reference line |
Settings and Connections 5 Chapter
Align the sync and subcarrier phases of the black burst signal to the reference line.
5 Output the player 1 signal from the
This displays the sync and subcarrier phases (composite signals only) of the signal from player 1.
7 On player 1, adjust the front panel SYNC PHASE and SC PHASE controls, using a Phillips screwdriver, so that the output from player 1 on channel A is in correct phase alignment with the black burst signal on channel B.
This indicator |
|
|
| This indicator |
|
|
| ||
moves as you |
| |||
| ||||
| moves as you | |||
turn the SYNC |
| |||
| turn the SC | |||
PHASE control. |
| |||
| PHASE control. | |||
|
|
|
|
Adjust the sync and subcarrier phases of the output signal from player 1.
92 Adjusting the Sync and Subcarrier Phases