Monitor problems
Symptom | Cause | Remedy | |
|
|
| |
Data is not | The CHARA. DISPLAY menu item is | Set the CHARA. DISPLAY menu item (see page 60) to ON. | |
superimposed on the | set to OFF. |
| |
monitor screen. |
|
| |
The monitor is not connected to the | Connect the monitor to the B− Y/CPST (SUPER) connector. | ||
| |||
| B− Y/CPST (SUPER) connector of this | (You must make this connection to display any type of text on | |
| unit. | the monitor.) | |
|
|
| |
The image on the | The 75 Ω termination switch for video | Set the 75 Ω termination switch to ON or connect a | |
monitor screen is too | input on the monitor is in the OFF | terminator. | |
bright. | position, or a 75 Ω terminator is not |
| |
| fitted to its video input connector. |
| |
|
|
| |
The image on the | In a video signal | Set the 75 Ω termination switches to OFF on all monitors | |
monitor screen is too | connection of video monitors, 75 Ω | other than the | |
dark. | termination switches for video input on |
| |
| monitors other than the |
| |
The image is too dark |
| ||
monitor are in the ON position. |
| ||
when recording a |
| ||
|
| ||
composite video |
|
| |
signal. |
|
| |
|
|
| |
|
|
| |
Audio problem |
|
| |
|
|
| |
Symptom | Cause | Remedy | |
|
|
| |
The REC/PB LEVEL | The VAR switch on the front panel is | Set the VAR switch to REC when recording, or set it to PB | |
control knobs do not | set to PRESET. | when playing back. | |
work. |
|
| |
|
|
| |
|
|
| |
Editing restriction |
|
| |
|
|
| |
Symptom | Cause |
| |
|
| ||
Execution of video | This phenomenon cannot be avoided with an editing system using this unit as the recorder. | ||
editing in insert mode |
|
| |
erases subcode data |
|
| |
(user bit data, etc.) |
|
| |
recorded on tape other |
|
| |
than time code data. |
|
| |
|
|
|
Troubleshooting and Maintenance 6 Chapter
Troubleshooting 97