4-3
PCS-1/PCS-1P
4-2. Setting of PCS-1 and HUB
The initial setting of the PCS-1 is Auto.
In the Auto setting of the PCS-1, 10/100 can be selected automatically, however, Half/Full cannot be selected
automatically. Therefore, if the HUB is set to Full mode, a connection failure or packet loss occurs. The following table
shows an example of connection between the PCS-1 and Catalyst 2950. When the HUB is set to 100FULL or 10FULL,
change the setting of HUB or adjust the PCS-1 setting to HUB. Refer to 2-5. Service Mode for the setting procedure of
the PCS-1.
Table of connection between PCS-1 and Catalyst 2950
PCS-1 setting AUTO 100FULL 100HALF 10FULL 10HALF
2950 settting
AUTO OK Packet loss OK Packet loss OK
100FULL Packet loss OK Packet loss Connection failure Connection failure
100HALF OK Packet loss OK Connection failure Connection failure
10FULL Packet loss Connection failure Connection failure OK Packet loss
10HALF OK Connection failure Connection failure Packet loss OK