Software Utility the Using 5 Chapter
Item name | Display contents |
Operation | Same as Operation |
Hours (r) | Hours (resettable a)) |
Laser | The cumulative light |
Parameter (r) | output time for the optical |
| head (resettable a)) |
Seek | The cumulative seek |
Running | operation time for the |
Hours (r) | optical head (unit: hours, |
| resettable a)) |
Spindle | The cumulative spindle |
Running | rotation time (unit: hours, |
Hours (r) | resettable a)) |
Loading | The total number of times |
Counter (r) | disc has been loaded |
| (resettable a)) |
a)This can be used as a guide in determining when to replace parts.
To refresh the display
Click the Refresh button.
Version information
The firmware version information includes the following items.
Item name | Display contents |
Package | The package version |
| when the firmware was |
| downloaded as a |
| package |
|
|
SY | System control software |
| version |
|
|
PIER | ”PIER” version of FPGA |
|
|
CAVE | ”CAVE” version of |
| FPGA |
|
|
Drive | Optical disc drive |
| system control software |
| version |
|
|
DSP | Audio DSP software |
| version |
|
|
Alarm log
This shows a maximum of 50 alarms generated since the unit was last powered on.
Select an item in the list to display details of that alarm (date and time of generation, and location on disc (time code)).
When the limit of 50 items on the list is exceeded, older alarms are deleted. Powering off the unit deletes all items from the list.
Refer to the utility software help for information about list of alarms.
5-3-2 Setup Menu
AV settings
Set the following items relating to this unit. In the Settings column of the table, underlined values indicate the factory default settings.
OPERATIONAL FUNCTION
Item name | Settings |
PREROLL | 0 SEC to 5 SEC to 30 |
TIME | SEC: Set the |
| preroll time to |
| between 0 and 30 |
| seconds in steps of |
| 1 second. A preroll |
| time of at least 5 |
| seconds is |
| recommended |
| when using this unit |
| for editing. |
|
|
50