Picture

S1

The VCR picture

t Make sure the TV is set to the video channel. If you are using a

 

does not appear on

monitor, set it to video input.

 

 

the TV screen.

t If the VCR is connected to the TV with a Scart cable, make sure the

 

 

TV/VIDEO indicator is lit in the display window. Use the TV/VIDEO

 

 

key on the remote commander to light the TV/VIDEO indicator.

 

 

t If your VCR is connected to the TV with only an aerial cable, make

 

 

sure the TV is correctly tuned to the VCR (see page 15).

 

 

 

S2

The TV programme

t If your TV is connected to the VCR with both a Scart and an aerial

 

is not clear or has

cable, make sure the RF channel is set to OFF (see page 17).

 

some interference.

t If your VCR is connected to the TV with only an aerial cable, make

 

 

sure the TV is correctly tuned to the VCR (see page 15).

 

 

 

 

S3

The playback picture

t If your TV is connected to the VCR with both

a Scart and an aerial

 

is not clear or has

cable, make sure the RF channel is set to OFF (see page 17).

 

some interference.

t Existing broadcasts may interfere with the VCR. Reset the RF

 

 

channel output of your VCR (see page 15).

 

 

 

t Adjust the tracking with the TRACKING +/– buttons (see page 62).

 

 

t The video heads are dirty (see below). Clean the video heads using

 

 

the Sony T-25CLD, E-25CLDR, or T-25CLW video head cleaning

 

 

cassette. If these cleaning cassettes are not available in your area,

 

 

have the heads cleaned at your nearest Sony service facility (a

 

 

standard service charge will be required). Do not use a commercially

 

 

available liquid type cleaning cassette other than Sony’s, as it may

 

 

damage the video heads.

 

 

 

t The video heads may have to be replaced. Consult your local Sony

 

 

service facility for more information.

 

 

 

 

S4

The tracking meter

t The recording condition of the tape is very poor and tracking cannot

 

does not appear on

be adjusted.

 

 

 

the TV screen.

 

 

 

 

 

 

S5

The picture rolls

t Adjust the vertical hold control on the TV or monitor.

 

vertically during

 

 

 

 

picture search.

 

 

 

 

 

 

 

 

Symptoms caused by contaminated video heads

 

 

• Normal picture

• Rough picture

Unclear picture

• No picture (or

 

 

 

 

black & white

 

 

 

 

screen appears)

initial

terminal

contamination

continued

Information

Additional

 

 

95

Page 95
Image 95
Sony SLV-SF900G manual Initial Terminal Contamination