Troubleshooting

 

 

 

Others

 

 

 

 

 

Symptom

Cause

Remedy

The LAMP/COVER indicator

The lamp cover or the air filter is

Attach the lamp cover or the air filter securely (see

flashes.

detached.

pages 34 (GB) and 35 (GB)).

 

 

 

The LAMP/COVER indicator

The lamp has reached the end of its life.

Replace the lamp (see page 34 (GB)).

lights up.

 

 

The lamp becomes a high temperature.

Wait for 120 seconds to cool down the lamp and

 

 

 

turn on the power again (see page 20 (GB)).

 

 

 

The TEMP/FAN indicator

The fan is broken.

Consult with qualified Sony personnel.

flashes.

 

 

 

 

 

The TEMP/FAN indicator

The internal temperature is unusually

Check to see if nothing is blocking the ventilation

lights up.

high.

holes.

 

 

Check to see if the air filter has been used over

 

 

500 hours.

 

 

Check to see if the air filter is clogged with dust.

Both LAMP/COVER and

The electric system failed.

Consult with qualified Sony personnel.

TEMP/FAN indicators light up.

 

 

 

 

 

 

 

 

Warning messages

 

 

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning

Remedy

 

 

 

High temp.!

Internal temperature is too high.

Turn off the power.

Lamp off in 1 min.

 

Check to see if nothing is blocking the ventilation

 

 

holes.

 

 

Check to see if the air filter has been used over

 

 

500 hours.

 

 

Check to see if the air filter is clogged with dust.

Frequency is out of range!

This input signal cannot be projected as

Input a signal that is within the range of the

 

the frequency is out of the acceptable

frequency.

 

range of the projector.

 

 

 

 

 

The resolution setting of the output

Set the setting of output to the XGA (see page 16

 

signal of a computer is too high.

(GB)).

 

 

 

Please check INPUT-A

You have input RGB signal from the

Set INPUT-A correctly (see page 27 (GB)).

setting.

computer when INPUT-A in the SET

 

 

SETTING menu is set to COMPONENT,

 

 

DTV YPBPR or DTV GBR.

 

 

 

 

Please check INPUT-B

You have input RGB signal from the

Set INPUT-B correctly (see page 27 (GB)).

setting.

computer when INPUT-B in the SET

 

 

SETTING menu is set to COMPONENT,

 

 

DTV YPBPR or DTV GBR.

 

Please replace the LAMP.

It is time to replace the lamp.

Please replace the lamp.

 

 

 

Please replace the filter.

The air filter is clogged with dust.

Please replace the air filter.

 

 

 

Caution messages

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning

Remedy

 

 

 

NO INPUT

No input signal

Check connections (see page 15 (GB) and 16 (GB)).

 

 

 

Not applicable!

You have pressed the wrong key.

Press the appropriate key.

 

 

 

37 (GB)