Example: &%SMCP0010$
Prints 16 (Hex 10) MICR lines before disabling MICR mode. This command defines how many MICR lines may print in the current job. When the count decrements to zero, MICR mode is terminated.
Set New Password Command &%STExxxxxxxx$
&%STE | Lead in sequence |
xxxxxxxx | New password, must be 8 characters either printable or non |
| printable. Dollar ($) sign is an invalid password character. |
$ | Command terminator. |
In order to set a new password the current password must first be sent. Caution: Errors made in sending the new password command could lead to setting it to an unknown value. If the Password is unknown the printer must be returned to Source Technologies to be reset to PASSWORD.
Activate/Set Front Panel Combination Lock | &%STSxxxxxxxx$ (optional) | |
&%STS | Lead in sequence |
|
xxxxxxxx | Eight digit sequence, valid characters | |
$ | Command terminator |
|
Sets and activates the front panel MICR combination lock. If this feature is activated, MICR mode cannot be entered until the front panel combination is entered correctly. All MICR features will be inaccessible until this combination is entered. Sending an &%STS command and eight zeros deactivates the security lock.
Caution: If the front panel combination is set and then forgotten, the printer must be returned to Source Technologies for the combination to be deactivated.
Print MICR | &%SMDddd...ddd$ |
&%SMD | Lead in sequence |
ddd...ddd | Data to be printed in |
$ | Command terminator |
Prints the specified data in the
Secure MICR Printer User’s Guide | 20 | © Source Technologies |
September 2005 | All Rights Reserved |