Audit Report Field Five | &%SQ5d..d$ |
&%SQ5 | Lead in sequence |
d..d | Data to be printed |
$ | Command terminator |
This command identifies the data to be printed in the fifth column of the report. This field is a maximum of eight characters.
Audit Report Field Six | &%SQ6d..d$ |
&%SQ6 | Lead in string |
d..d | Data to be printed |
$ | Command terminator |
This command identifies the data to be printed in the sixth column of the report. This field is a maximum of 19 characters.
Audit Report Field Seven | &%SQ7d..d$ |
&SQ&7 | Lead in string |
d..d | Data to be stored |
$ | Command terminator |
This command identifies the data to be printed in the seventh column of the report. This field is a maximum of 12 characters. The data in this field is recorded for the Audit Report only.
Print and Purge Audit Report &%SPURGExx$
&%SPURGE | Lead in string |
x | option(s) |
$ | Command terminator |
This command prints and purges the Audit Report. All recorded information is deleted. The optional field can be any combination of the following letters:
T Total Field 4
O Overlay
S Sort by MICR line
CCommunicate - send report to host instead of printing - see additional information below on SPRINT command
Secure MICR Printer User’s Guide | 39 | © Source Technologies |
September 2005 | All Rights Reserved |