Southbend SB Additional Component Wiring, 220VAC L6-30 Plug as recommended, Power Connection

Models: SB

1 132
Download 132 pages 6.05 Kb
Page 96
Image 96
Additional Component Wiring

 

E L E C T R I C A L

 

13" Heavy 13® Gearhead Lathe

For Machines Mfg. Since 5/11

 

 

 

Additional Component Wiring

End Gear Cover

Safety Switch

3

0

Figure 141. End Gear Cover Safety switch location.

Chuck Guard

Safety

Switch

Figure 142. Chuck Guard Safety switch location.

To Electrical

Cabinet

Page 90

Work Light

End Gear Cover Micro Switch

Figure 141

 

COMMON

 

 

NO

-1307

 

 

TM

0

NC

Tend

 

 

 

End Gear CoverFigure 141. End Gear Cover Safety switch location. A1X

Chuck Guard Limit Switch

Figure 142

3

SwitchCabinetWork LightChuck Guard Limit SwitchBrake Pedal Micro Switch220VAC NC MasterManual background NO

Manual backgroundManual backgroundManual backgroundA1Manual background

Tend TZ-9212 X1

NC

4

NO

Brake Pedal Micro Switch

Figure 137

14

13

X2

 

Tend TM-1704

 

4

 

22

21

Power Connection

Ground

Hot

Ground

L1

 

Hot

 

L2

G

220VAC

L6-30 Plug

(as recommended)

Inside Electrical

Cabinet

Page 90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

L2

 

 

 

 

 

 

 

 

3

15

Master

Power

Switch

26

Manual background 4 Manual background

L1

 

L2

 

 

 

 

 

 

 

 

 

 

-94-